Specifications
Table Of Contents
- TABLE OF CONTENTS
- CAUTION
- Foreword
- For safe operation
- How to Read This Operation Manual
- CHAPTER 1 Before Use
- CHAPTER 2 Basic Operations
- CHAPTER 3 Useful Function
- Changing origin
- Adjusting head gap
- When nozzles missing can not be improved
- Setting the print condition in a set
- Setting the print condition
- Setting media compensation
- Setting the print method
- Registering head gap value
- Set the scan width of the head
- Changing the UV illumination intensity
- Sets UV irradiation at starting/ ending of drawing
- Setting the priority
- Sets the cooling time per scan
- Initializing the settings
- Turning OFF the UV lamp
- Setting the UV lamp OFF duration
- Changing the UV illumination intensity
- MACHINE SETUP
- Other useful functions
- CHAPTER 4 How to care
- Maintaining
- Ink cartridge
- Washing cartridge
- Cleaning the flushing box
- Avoiding ink dripping at printing
- When the waste ink tray is full
- Setting nozzle face cleaning time
- Perform cleaning automatically when the power supply is turned on
- Preventing nozzle dropout while power-off
- Regular maintenance of white ink
- If blur or missing remains
- Wiper cleaning
- Refill antifreeze liquid
- Cleaning of the UV lamp filter
- Cleaning of the UV power supply filter
- Cleaning of the optional vacuum unit filter
- Replacing the mist fan filter
- Replacing UV lamp
- Checking method of UV illumination intensity
- Cleaning of the Ionizer
- Prevent the nozzle clogging of spot color
- CHAPTER 5 In Case of Trouble
- CHAPTER 6 Appendix

3-22
Sets the cooling time per scan
When you print on the media that will be deformed by heat of the UV lamp, set the machine so that the
media will be cooled per scan.
1
When <LOCAL> is displayed, press the
key.
2
Press the key.
3
Select the type 1 to 4 with the
key, and press the key.
4
Select the [COOLONG TIME] with the
key, and press the
key.
5
Set the cooling time with the
key, and press the key.
• Setting Value: 0.0 to 2.0s
6
Press the key to finish.
• Please do not store combustible materials near the flushing BOX.
<LOCAL . 1>
FUNCTION
FUNCT I ON
SET UP <ENT>
ENTER
SET UP
SELECT : TYPE1
ENTER
[1]
COOL I NG T I ME < e n t >
ENTER
[1]COOLING TIME
SET UP : 0 . 0 s
ENTER
END