that the UI poses on the user. First select the TX Power Calibration from Calibration at the main menu. When
done the following control is shown:
Press start to initiate the power calibration.
Proceed with Cal Tx1 to calibrate the 1st transmitter or with Cal Tx2 to do the 2nd one. The order isn't important.
The power at the current state is down and the carrier is turned On once one of these buttons is pressed.
6.5.1 CALIBRATING TX (COARSE STEP)
Once we press Cal Tx1 the carrier power is turned on for transmitter 1 (transmitter 2 is Off) and user is ready to
measure output power (uncalibrated output). The following page will allow to input the measured power and perform
the 1st step of calibration (the coarse step),
During this step the duplexer loss in the RF EEPROM will be adjusted once Calibrate is pressed. This click will
take the user to the 2nd calibration step, called the fine step.
6.5.2 CALIBRATING TX (FINE STEP)
The fine step is where the power is accurately adjusted using the PG (aka Pulse Shaper Gain) - the digital gain
and digital hardware method to control power. Click Calibrate on the following page to apply it,