RSSI calibration can be easily achieved by following the instructions step by step. Below is the summary of the
procedure that is also shown on the RSSI Calibration page below (Calibration > RSSI Calibration).
1. Connect signal generator via a 30dB attenuator to Channel 1 receiver.
2. Set signal generator level so that -40dBm can be measured at the receiver input. Choose un-modulated
carrier for the input signal.
3. Select Rx1 in the CCMS page.
4. Select -40dBm in the CCMS page.
5. Click Read in the CCMS page.
6. Set signal generator level so that -90dBm can be measured at the receiver input.
7. Select -60dBm in the CCMS page.
8. Click Read in the CCMS page.
9. Click Calculate in the CCMS page.
10. Click Save in the CCMS page.
11. Connect signal generator via a 30dB attenuator to Channel 2 receiver.
12. Repeat Step 2 to 10 for the Channel 2 receiver.
RSSI Calibration Page