Technical data
EN
2.2  GENERAL VIEW OF THE MACHINE
1.  Welding gun 
2.  Earthing cable 
3.  Main switch 
4.  Supply voltage cable 
5.  Shielding gas hose connector 
2.3  DISTRIBUTION NETWORK
All regular electrical devices without special circuits generate harmonic 
currents into distribution network. High rates of harmonic current may cause 
losses and disturbance to some equipment.
WARNING: This equipment does not comply with IEC 61000-3-12. If it is 
connected to a public low voltage system, it is the responsibility of the 
installer or user of the equipment to ensure, by consultation with the 
distribution network operator if necessary, that the equipment may be 
connected.
2.4  CABLE CONNECTIONS 
Connection to the mains 
The machine is equipped with a 3.3 m long supply voltage cable and plug. 
Connect the supply voltage cable to the mains. 
NOTE! The fuse size needed is 16 A delayed. 
If you use an extension cord, its cross-sectional area should be at least as 
large as the supply voltage cable’s (3 x 2.5 mm²). The maximum length for the 
extension cord is 50 m. 
6