User Manual
Table Of Contents
- 08-0308 - Manual Cover.pdf
- 0070-10-0690-01 Panorama Operations Maual with Telepack 2.4 - CH16 REVISED2.pdf
- Foreword
- Warnings, Precautions and Notes
- Indications for Use
- Unpacking Information
- Symbols and Descriptions
- Technical Support
- 1.0 System Overview
- 1.1 Components of the Panorama System
- 1.2 Licensing Key
- 1.3 Supported Devices
- 1.3.1 Panorama Central Station
- 1.3.2 Panorama ViewStation and WorkStation
- 1.3.3 Panorama Telemetry Server
- 1.3.4 Panorama Wireless Transceiver
- 1.3.5 Panorama Gateway
- 1.3.6 Panorama Web Viewer
- 1.3.7 Passport 2® Bedside Monitor
- 1.3.8 Spectrum™ Bedside Monitor
- 1.3.9 Spectrum OR™ Bedside Monitor
- 1.3.10 Panorama Telepack
- 1.3.11 Network Printer
- 1.4 Troubleshooting
- 2.0 Getting Started
- 3.0 Alarm Behavior
- 4.0 Arrhythmia and ST Analysis
- 5.0 Patient Setup Functions
- 5.1 Demographics Tab
- 5.2 Transfer Tab
- 5.3 Discharge Tab
- 5.4 Display Tab
- 5.5 Standby Tab
- 5.6 Wave Gain Tab (Patient)
- 5.7 Print Setup Tab (Patient)
- 6.0 Patient Alarm Functions
- 7.0 Views
- 7.1 Bedside Tab
- 7.2 Trends Tab
- 7.3 Events Tab
- 7.4 Disclosure Tab
- 7.4.1 Accessing the Disclosure Tab
- 7.4.2 Disclosure Tab (Waveforms View)
- 7.4.2.1 Accessing the Waveforms View
- 7.4.2.2 Components of the Waveforms View
- 7.4.2.3 Navigating in the Waveforms View of the Disclosure Tab
- 7.4.2.4 ST Button
- 7.4.2.5 Comments Dialog Box (Optional)
- 7.4.2.6 Sidebar Buttons
- 7.4.2.7 Printing a Full Disclosure Zoom In Report from the Waveforms View
- 7.4.2.8 Troubleshooting
- 7.5 ST Tab
- 8.0 Report Functions
- 8.1 Patient Reports Tab
- 8.2 System Reports Tab
- 8.3 Print Status Tab
- 8.4 Additional Reports
- 9.0 System Setup Functions
- 9.1 Parameter Color Tab
- 9.2 Touch Screen Tab
- 9.3 Installation Setup Tab
- 9.4 Care Group Tab
- 9.5 Volume Tab
- 9.6 System Alarms Tab
- 9.7 Passwords Tab
- 9.8 Equipment Setup Tab
- 9.9 More Tab
- 9.10 Previous Tab
- 9.11 Date/Time Tab
- 9.12 Print Setup Tab (System)
- 9.13 Unit Priorities Tab
- 9.14 Unit Choices Tab
- 9.15 Wave Gain Tab (System)
- 9.16 Wireless Tab
- 10.0 Telepack (Optional)
- 11.0 User Maintenance
- 12.0 Parameter Specifications
- 12.1 Parameter Specifications
- 12.1.1 Heart Rate: HR
- 12.1.2 Respiration: Resp
- 12.1.3 NIBP
- 12.1.4 SpO2
- 12.1.5 Nonin SpO2
- 12.1.6 IBP: mmHg
- 12.1.7 CO2
- 12.1.8 O2
- 12.1.9 INSP/ET O2
- 12.1.10 N2O
- 12.1.11 Anesthetic Agents: Iso, Enf, Des, Sev, Hal, Agent
- 12.1.12 Premature Ventricular Contraction (PVC)
- 12.1.13 Temp: T1,T2, Delta T, and T Blood
- 12.1.14 ST
- 12.1.15 Cardiac Output
- 12.1.16 Cardiac Index
- 12.1.17 Pulmonary Artery Wedge Pressure (PAWP)
- 12.1.18 Battery Percentage
- 12.2 Invalid Data Display
- 12.1 Parameter Specifications
- 13.0 Alarms and Events
- 14.0 Network Tab (Optional)
- 14.1 Network Tab
- 14.1.1 Accessing the Network Tab
- 14.1.2 Sorting the Contents of the Network Tab List Box
- 14.1.3 Assigning Patient Tiles in the Network Tab
- 14.1.4 Removing a Patient Tile Assignment in the Network Tab
- 14.1.5 Removing All Patient Tile Assignments in the Network Tab
- 14.1.6 Refreshing the Network Tab List Box
- 14.1.7 Troubleshooting
- 14.1 Network Tab
- 15.0 Paging Tab (Optional)
- 15.1 Paging Password Tab
- 15.2 Paging Tab
- 15.2.1 Accessing the Paging Tab
- 15.2.2 Adding a Pager
- 15.2.3 Assigning a Patient Tile
- 15.2.4 Adding All Patient Tiles to a Pager
- 15.2.5 Removing a Patient Tile Assignment
- 15.2.6 Removing All Patient Tiles from a Pager
- 15.2.7 Editing a Pager
- 15.2.8 Removing a Pager
- 15.2.9 Resending a Failed Page
- 15.2.10 Generating a Paging Report
- 15.2.11 Troubleshooting
- 17.0 Glossary
Alarm Limits Tab (Patient) Patient Alarm Functions
6 - 8 0070-10-0690-01 Panorama™ Operating Instructions
Suspend All Alarms (Optional)
Select the Suspend All Alarms sidebar button to suspend, for a user configured period of
time, all numeric physiological, lethal arrhythmia, non-lethal arrhythmia, and technical
alarms at the Panorama Central Station for the selected patient tile. The Suspend All
Alarms sidebar button is only shown if the Suspend Alarms option is ON in the System
Alarms tab.
WARNING: When the Suspend All Alarms sidebar button is enabled, the
Panorama Central Station will not monitor any lethal or
non-lethal arrhythmias and will not display numeric
physiological or technical alarms for the selected patient tile.
NOTE: The Suspend All Alarms sidebar button is not available at
the ViewStation.
NOTE: The amount of time an alarm is suspended is dependent on
the configured System Suspend All Timeout setting.
When the Suspend All Alarms sidebar button is selected:
•The Suspend All Alarms sidebar button changes to white with black text.
•The All Alarms Suspended message displays in red text in the Patient Status line of
the patient tile. For additional information regarding the Patient Status line, refer to the
‘‘Patient Status Line’’ on page 2-10.
To resume the monitoring of alarms, select the Suspend All Alarms sidebar button.
• When the Suspend All Alarms sidebar button is disabled, the button changes to blue
with white text. Alarms are now re-enabled for the selected patient.
Suspend Non-Lethal
Select the Suspend Non-Lethal sidebar button to suspend all numeric, technical and
non-lethal arrhythmia alarms for the selected patient tile. Lethal arrhythmia alarms continue to
be monitored at the Panorama Central Station when non-lethal arrhythmia alarms are
suspended.
WARNING: When the Suspend Non-Lethal alarms sidebar button is
enabled, the Panorama Central Station will not monitor any
non-lethal arrhythmias, and will not display numeric
physiological or technical alarms for the selected patient tile.
NOTE: The Suspend Non-lethal sidebar button is not available at
the ViewStation.
NOTE: The Brady alarm will not be suspended when the Suspend
Non-Lethals sidebar button is selected.
When the Suspend Non-Lethal button is selected:
•The Suspend Non-Lethal sidebar button changes to white with black text.
•The Non-Lethal Alarms Suspended message displays in yellow text in the Patient
Status line of the patient tile. For additional information regarding the Patient Status line,
refer to the ‘‘Patient Status Line’’ on page 2-10.
To resume the monitoring of non-lethal alarms, select the Suspend Non-Lethal sidebar
button.