User Manual
Table Of Contents
- 08-0308 - Manual Cover.pdf
- 0070-10-0690-01 Panorama Operations Maual with Telepack 2.4 - CH16 REVISED2.pdf
- Foreword
- Warnings, Precautions and Notes
- Indications for Use
- Unpacking Information
- Symbols and Descriptions
- Technical Support
- 1.0 System Overview
- 1.1 Components of the Panorama System
- 1.2 Licensing Key
- 1.3 Supported Devices
- 1.3.1 Panorama Central Station
- 1.3.2 Panorama ViewStation and WorkStation
- 1.3.3 Panorama Telemetry Server
- 1.3.4 Panorama Wireless Transceiver
- 1.3.5 Panorama Gateway
- 1.3.6 Panorama Web Viewer
- 1.3.7 Passport 2® Bedside Monitor
- 1.3.8 Spectrum™ Bedside Monitor
- 1.3.9 Spectrum OR™ Bedside Monitor
- 1.3.10 Panorama Telepack
- 1.3.11 Network Printer
- 1.4 Troubleshooting
- 2.0 Getting Started
- 3.0 Alarm Behavior
- 4.0 Arrhythmia and ST Analysis
- 5.0 Patient Setup Functions
- 5.1 Demographics Tab
- 5.2 Transfer Tab
- 5.3 Discharge Tab
- 5.4 Display Tab
- 5.5 Standby Tab
- 5.6 Wave Gain Tab (Patient)
- 5.7 Print Setup Tab (Patient)
- 6.0 Patient Alarm Functions
- 7.0 Views
- 7.1 Bedside Tab
- 7.2 Trends Tab
- 7.3 Events Tab
- 7.4 Disclosure Tab
- 7.4.1 Accessing the Disclosure Tab
- 7.4.2 Disclosure Tab (Waveforms View)
- 7.4.2.1 Accessing the Waveforms View
- 7.4.2.2 Components of the Waveforms View
- 7.4.2.3 Navigating in the Waveforms View of the Disclosure Tab
- 7.4.2.4 ST Button
- 7.4.2.5 Comments Dialog Box (Optional)
- 7.4.2.6 Sidebar Buttons
- 7.4.2.7 Printing a Full Disclosure Zoom In Report from the Waveforms View
- 7.4.2.8 Troubleshooting
- 7.5 ST Tab
- 8.0 Report Functions
- 8.1 Patient Reports Tab
- 8.2 System Reports Tab
- 8.3 Print Status Tab
- 8.4 Additional Reports
- 9.0 System Setup Functions
- 9.1 Parameter Color Tab
- 9.2 Touch Screen Tab
- 9.3 Installation Setup Tab
- 9.4 Care Group Tab
- 9.5 Volume Tab
- 9.6 System Alarms Tab
- 9.7 Passwords Tab
- 9.8 Equipment Setup Tab
- 9.9 More Tab
- 9.10 Previous Tab
- 9.11 Date/Time Tab
- 9.12 Print Setup Tab (System)
- 9.13 Unit Priorities Tab
- 9.14 Unit Choices Tab
- 9.15 Wave Gain Tab (System)
- 9.16 Wireless Tab
- 10.0 Telepack (Optional)
- 11.0 User Maintenance
- 12.0 Parameter Specifications
- 12.1 Parameter Specifications
- 12.1.1 Heart Rate: HR
- 12.1.2 Respiration: Resp
- 12.1.3 NIBP
- 12.1.4 SpO2
- 12.1.5 Nonin SpO2
- 12.1.6 IBP: mmHg
- 12.1.7 CO2
- 12.1.8 O2
- 12.1.9 INSP/ET O2
- 12.1.10 N2O
- 12.1.11 Anesthetic Agents: Iso, Enf, Des, Sev, Hal, Agent
- 12.1.12 Premature Ventricular Contraction (PVC)
- 12.1.13 Temp: T1,T2, Delta T, and T Blood
- 12.1.14 ST
- 12.1.15 Cardiac Output
- 12.1.16 Cardiac Index
- 12.1.17 Pulmonary Artery Wedge Pressure (PAWP)
- 12.1.18 Battery Percentage
- 12.2 Invalid Data Display
- 12.1 Parameter Specifications
- 13.0 Alarms and Events
- 14.0 Network Tab (Optional)
- 14.1 Network Tab
- 14.1.1 Accessing the Network Tab
- 14.1.2 Sorting the Contents of the Network Tab List Box
- 14.1.3 Assigning Patient Tiles in the Network Tab
- 14.1.4 Removing a Patient Tile Assignment in the Network Tab
- 14.1.5 Removing All Patient Tile Assignments in the Network Tab
- 14.1.6 Refreshing the Network Tab List Box
- 14.1.7 Troubleshooting
- 14.1 Network Tab
- 15.0 Paging Tab (Optional)
- 15.1 Paging Password Tab
- 15.2 Paging Tab
- 15.2.1 Accessing the Paging Tab
- 15.2.2 Adding a Pager
- 15.2.3 Assigning a Patient Tile
- 15.2.4 Adding All Patient Tiles to a Pager
- 15.2.5 Removing a Patient Tile Assignment
- 15.2.6 Removing All Patient Tiles from a Pager
- 15.2.7 Editing a Pager
- 15.2.8 Removing a Pager
- 15.2.9 Resending a Failed Page
- 15.2.10 Generating a Paging Report
- 15.2.11 Troubleshooting
- 17.0 Glossary
Unit Choices Tab System Setup Functions
9 - 52 0070-10-0690-01 Panorama™ Operating Instructions
3. Select the Pacer Reject button to select the system default pacer reject period. Pacer
Reject adjusts the time period at which pacemaker-induced ECG complexes are filtered
for ECG sampling processes.
Pacer Reject options include 0 to 80 milliseconds (ms) in 20-second increments. The
factory default setting is 40 ms.
NOTE: Changing the Pacer Reject option will affect all newly
admitted patients and will have no affect on patients
currently being monitored.
NOTE: The Pacer Reject option is not available at the ViewStation
or the WorkStation.
4. Select the Paging Demographics button to define which demographic information is
sent to the paging system when a page is requested. Paging Demographics options
include Bed, Bed + Last Name, and Bed + ID. The factory default setting is Bed.
Refer to the following tables for formatting examples:
NOTE: The amount of data that is displayed in the pager display
window may differ slightly due to the type of pager being
used.
NOTE: Changing the Paging Demographics option will take effect
immediately.
OPTION ALARM TYPE FORMAT EXAMPLES
Bed Heart Rate central name:XXXBed:ICU10 Low Heart Rate Alarm
Bed Arrhythmia central name:XXXBed:ICU10 Asystole
Bed Not HR or
arrhythmia alarm
central name:XXXBed:ICU10 High Temperature 1
Bed ST alarm central name:XXXBed:ICU10 ST Single Alarm
OPTION ALARM TYPE FORMAT EXAMPLES
Bed + Last
Name
Heart Rate central name:XXXBed:ICU10 Name:Patient Last Name
Low Heart Rate Alarm
Bed + Last
Name
Arrhythmia central name:XXXBed:ICU10 Name:Patient Last Name
Asystole
Bed + Last
Name
Not HR or
arrhythmia alarm
central name:XXXBed:ICU10 Name:Patient Last Name
High Temperature 1
Bed + Last
Name
ST alarm central name:XXXBed:ICU10 Name:Patient Last Name ST
Single Alarm
OPTION ALARM TYPE FORMAT EXAMPLES
Bed + ID Heart Rate central name:XXXBed:ICU10 ID:Patient ID Low Heart Rate
Alarm
Bed + ID Arrhythmia central name:XXXBed:ICU10 ID:Patient ID Asystole
Bed + ID Not HR or
arrhythmia alarm
central name:XXXBed:ICU10 ID:Patient ID High
Temperature 1
Bed + ID ST alarm central name:XXXBed:ICU10 ID:Patien
t ID ST Single
Alarm