User's Manual

Personal Node User Manual
14 / 70
Rev: 1.1
©
c
Minete
01
2
9
To ensure that the Personal Node cannot be turned off accidently, or forgotten to be turned on, it
does not have an ON/OFF switch. The Personal Node is only off when it has a totally flat battery or
when it is being charged in the Personal Node Charging Dock. The device turns on automatically
when removed from the Personal Node Charging Dock.
4.1.1 Proximity event alarms
A visible and audible alarm annunciates when a proximity event triggers indicating a vehicle has been
detected within one of the proximity zones. The audible alarm is an intermittent beep with a
configurable duty cycle. The LEDs colours are also configurable.
The configurable parameters of the alarm are a tone frequency between 500 Hz and 3000 Hz and a
typical duty cycle in the range of 10%-50%. The default alarms are shown in Table 4 Basic default
alarms on page 14.
Figure
6
Swivel belt clip
-
Pin
Label recess
Standard
belt
loop in
horizontal
orientation
M3
x
10
mm SEMS screws
(
Torx driver), 6x
Swivel pin