User's Manual

Personal Node User Manual Section 4 Working with the Personal Node
27 / 70
Rev: 1.1
©
c
Minete
01
2
9
Normal operation (SafeDetect™ only)
PROXIMITY EVENT PATTERN
A visible and audible warning is active, as
one or more vehicles are nearby.
Audible warning will stop when the device
is muted, visible warning will continue.
Respond to all warnings in line with onsite
operational and HSE policies and
procedures
All LEDs flash in synchronisation
with the audible alarm
appropriate for the zone.
For the default patterns, see
Table 6 Function overview
(defaults) on page 18 and
Proximity event alarms on page
13.
Normal operation (SafeDetect™ only)
Broadcast Me PATTERN
To cancel Broadcast Me, press and hold
the device button for two seconds.
All LEDs continuously flash
white along accompanied by
any configured audible alert.
For the default patterns, see
Table 6 Function overview
(defaults) on page 18 and
Proximity event alarms on page
13.
Operation/Function
Pattern
LED Display
Normal operation (SafeDetect™ only)
IVD PATTERN
The Personal Node is suppressed from
being detected by mobile nodes. Used
when entering a vehicle.
The Status LED is a solid colour;
no audible alert.
The LED colour reflects the current
status (green for normal, orange for
low battery etc) and activating IVD
just prevents the Status LED from
flashing.
This example shows IVD when
in normal operation with a
green Status LED