Personal Node User Manual Section 5 Everyday operation
35 / 70
Rev: 1.1
©
c
Minete
01
2
9
Step
Action/Response
Comments
1) Enter the
vehicle
Follow site procedures.
No alarms will annunciate if the system
is off.
2) Start the
system.
The system starts when the vehicle
power supply is applied.
The vehicle nodes are active within
5 seconds of power applied so the vehicle is
visible to other vehicles and pedestrians
within 5 seconds.
The In-Vehicle PC starts automatically
within 40 seconds.
3) Confirm the In-
Vehicle PC is
operational
Refer to the SafeDetect Operator
Manual for details on the In-Vehicle
PC.
Eventually the Personal Node proximity
alarm activates and the alarm pattern
exhibits.
The In-Vehicle PC also annunciates an
alarm.
4) Enter IVD
mode.
Press the Personal Node button twice
within two seconds and confirm that:
o The audible alarm mutes.
o The Status LED illuminates solid
green.
See IVD pattern on page 25.
5) Confirm IVD on
vehicle display
In the vehicle, confirm on the
In-Vehicle PC that the Personal Node
ID is:
Added to the IVD list.
Removed from the warning zone
panel and warnings list.
The audible alarm mutes.
Tap the vehicle icon in the centre of
the screen to open the Driver
Identification screen which includes the
IVD list.
Refer to the SafeDetect Operator
Manual for details on the In-Vehicle
PC.
Procedure 5 Cancelling IVD mode
The Personal Node IVD mode is cancelled by any of the following events:
1) Manual deactivation by pressing the device button twice within two seconds. This is the
recommended and expected default action.
2) Automatic deactivation when the:
a) Driver walks outside the IVD outer zone from the vehicle and the user has forgotten to
cancel IVD mode. Refer About In-Vehicle Detection on page 20.
b) System is turned off.
Once IVD mode is cancelled, the user will still be within the STOP zone and the
Personal Node STOP zone alarm annunciates.