User's Manual

Personal Node User Manual Section 8 Maintenance activities
53 / 70
Rev: 1.1
©
c
Minete
01
2
9
All required hardware is available (eg spares battery packs).
Appropriate PPE (eg gloves for cleaning fluids).
Guide 1 Checking Personal Node
This guideline provides basic checks of the Personal Node for use in SafeDetect or Trax. If the device
has shown any faults (in or out of the dock) then refer to the Personal Node troubleshooting on page
57.
Refer to the following when performing the operational checks:
Table 9 Regular operating patterns on page 24.
Table 10 Irregular operating patterns on page 26.
Check the following and act accordingly:
Step
Check
Action
Remediation
Notes/References
1)
Charging
Check the Personal Node is
charging in the dock.
CHARGE LED should be solid red
(charging) or solid green
(charged).
Perform
troubleshooting.
Personal Node
troubleshooting on page
57.
Note that if SafeDetect is
operational at site and vehicles
are nearby, the Personal Node
may start to alarm. This is
normal.
2)
Start-up
Remove the Personal Node
from the dock and check the
Personal Node start-up
pattern.
See Table 8 Start-up
sequence on page 23.
3)
Ready for
use
Check Status LED is correct.
STATUS LED flashes green, once
every two seconds
4)
Cleanliness
Check the body and
mounting clip of the
Personal Node is clean and
clear of any accretions (mud,
dust etc).
If required, the
outside surface can
be cleaned with a
damp cloth.
Do not use any harsh abrasives,
liquids or detergents.
Do not wash with high pressure
water.
This guideline excludes SafeDetect functional and alarm checks.
Wear protective gloves if handling electrical contact cleaner and refer to the MSDS.