When evacuating the air-conditioning system, refrigerant oil is also extracted and collected in the oil separator
of the service station.
After evacuation, the refrigerant must be filtered in the service station as the oil separator could still contain a
liquid refrigerant/oil mixture. The filtering process gasifies the refrigerant completely and only the previously
b
ound refrigerant oil remains in the oil separator. Measure and note down this quantity of refrigerant oil, refer to
64 50 009 DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R 134A).
Fig. 49: View Of Oil Separator
Courtesy of BMW OF NORTH AMERICA, INC.
Set all air vents in instrument cluster to "OPEN".
Start engine and let it stabilize at idle speed.
Set blower output to min. 75% of max. blower output.
Switch on A/C system and run for at least 2 minutes at idle speed (risk of
damage at higher speed!).