3  ACOUSTIC MEASUREMENT 
The Dirac Live Calibration Tool For miniDSP uses a set of measurements made in your listening room to gather 
all the acoustical information about your room and speakers that it needs to calculate the correction filters. The 
measurements are made using the nanoAVR DL HDMI audio processor and a miniDSP UMIK-1 measurement 
microphone (must be purchased separately). 
3.1  LOUDSPEAKER AND MICROPHONE POSITIONING 
Prior to performing acoustic measurements, loudspeaker and subwoofer positioning should be optimized. In 
particular, the location of the subwoofer within the room will have a large impact on the smoothness of bass 
response. With Dirac Live®, you have more freedom with loudspeaker and subwoofer placement, but the best 
result will still be achieved if optimal placement is used together with Dirac Live®.  
A total of nine measurements are needed, with the microphone located in different positions in the room and 
pointed vertically (that is, at the floor or ceiling). The first measurement must be taken at the central location of 
the listening area, as this location sets the levels and delays of each speaker. Eight more measurements are then 
taken at locations spread around the listening area and at different heights from the floor. 