Specifications

Please DO NOT use this switch to control Medical or Life Support equipment. Z-Wave devices should never be used to
control the On / Off status of Medical and / or Life Support equipment.
• DO NOT EXCEED RATINGS
• DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION COULD
CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances. Reason being is because the appli-
ance you want to control may be in a separate room and if unintentional behavior occurs (such as adevice turning on or off -
either intentionally via schedules, or unintentionally via network error) this event may lead to a hazardous condition. For the
se
reasons, please note the following suggestions:
due to unattended, unintentional, or automatic power control.
1) Do not include Z-Wave devices in Groups or Scenes if they control appliances.
2) Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition
2. Your device may need to be within 100 feet of the controller to be included. If so, include the device to the network
within 10 feet of the controller and relocate it to the
desired position in your home. Be sure to refresh the network if the device is included
in this manner.
1. Plug the device you want to control into the Z-Wave Smart plug controlled outlet.
NOTE: Plug directly into the outlet, do not use with power strip.
Notes:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufa-
cturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of
vendor to increase the reliability of the network. This Device supports Lifeline (association group 1) supporting 1 node for
lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will
be sent. The Z-Wave controller should set this association automatically after inclusion. Lifeline association only supports the
“Device Reset Locally” function.
1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
2. Once the controller is ready to remove your device, press the manual/program button on the smart plug 3 times quickly.
Z-Wave Network Configuration
Adding Device To Z-Wave Network
Again: If you have issues with pairing / including, please move the device as close as possible to the hub and try again--you
can move to your final location when completed.
Note: If the manual button doesn't light up after pressed 3 times, please reset the
Device: click the button twice quickly then hold for at least 10 seconds. This operation could be done when manual control
is functional--single press can turn on / off the lamp.
1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
2. Once the controller is ready to add your device, press the Manual/ Program button on the smart plug 3 times quickly. The
blue LED will blink quickly. Auto-add mode: LED will blink within 30 seconds after first plugged in. Now, you have complet-
ed control to turn your fixture ON/OFF according to groups, schedules and interactive automation programmed by your
controller. If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices.
Group 1 supports 1 node ID,Group 2 Supports maximum of 5 node ID’s
Association Group 1: Z-Wave Plus Lifeline
Association Group 2: Send Basic Set ON / Off
If you'd like to reset the KWH record, just click the button 10 times very quickly. Network exclusion or factory reset will
NOT automatically erase the KWH data.
Manual: Click the button twice quickly then hold for at least 10 seconds. (Light flashes once when reset successfully.)
Host reset: Remove it from hub the device will be restore to factory default.
Parameter Settings
Our Products warrant this product to be free from manufacturing defects for a period of one year from the original date of
consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to cons-
equential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other war-
ranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the excl-
usion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives
you specific rights, and you may also have other rights which vary from state to state.
Warranty
KWH Reset:
To Return The Device To Factory Defaults:
To Remove The Device:
Association Group:
Adding Device To Z-Wave Network for QR CODE
Scan here for SmartStar inclusion
Note: DSK Code can be found on the packaging box.
Do not remove or damage them.
Program button
Press 1x: Manually
Press 3x: Z-Wave Network configuration
Reset: Press the button twice then hold it for 10 seconds
LED indicator
Blue: Light status indicator
Blue: ADD / Inclusion
Purple: Remove / Exclusion
Red: Network Failure / Over-temperature Warning
MP21ZD (ZW39SU)
Z-Wave Dimmer plug
Indoor use in dry location
Specification
Input: 125VAC 60Hz
Frequency: 908.42 MHz
100W Dimmable CFL/LED
Loading: 200W Incandescent
Features:
1. Z-Wave on / off + dimmer control.
2. Grounded 3-wire power connection for safety.
3. Remember and restore on/off status after power failure.
5. S2 security and 700 Z-Wave chip for reliable wireless communication.
6. Work with all certificated Z-Wave controllers.
4. Built-in Z-Wave Plus signal repeater to extend network range.
Please contact us if you have any questions:
ask@minoston.com
www.minoston.com
Z-WAVE INTEROPERABILITY
FCC / IC
This device complies with part 15 of the FCC and Industry Canada license-exempt RSS standard(s). Operation is subjected
to the following two conditions: (1) This device may not cause harmful interference, (2) This device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to
this equipment. Such modifications could void the user’s authority to operate the equipment.
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio / TV technician for help.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential ins-
tallation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interfe-
nce will not occur in a particular installation. If this equipment does cause harmful interference to radio or television recepre-
tion, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
CAUTION - PLEASE READ!
This device is intended for installation in accordance with the National Electric Code and local regulations in the United States,
or the Canadian Electrical Code and local regulations in Canada If you are unsure or uncomfortable about performing this
installation consult a qualified electrician.
WARNING
RISK OF FIRE / RISK OF ELECTRICAL SHOCK / RISK OF BURNS
TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUN-
DING TYPE PLUG THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL
ONLY FIT INTO A GROUNDING TYPE POWER OUTLET. IF THE PLUG DOES
NOT FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO
INSTALL THE PROPER
OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
CONTROLLING APPLIANCES:
CAUTION: TO REDUCE THE RISK OF
OVERHEATING AND POSSIBLE DAMAGE TO
OTHER EQUIPMENT
COMMANDCLASS:
0x5E - ZWAVEPLUS_INFO
0x25 - SWITCH_BINARY
0x70 - CONFIGURANTION
0x85 - COMMAND_CLASS_ASSOCIATION
0x8E - COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
0x59 - COMMAND_CLASS_ASSOCIATION_GRP_INFO
0x55 - COMMAND_CLASS_TRANSPORT_SERVICE
0x86 - COMMAND_CLASS_VERSION
0x72 - COMMAND_CLASS_MANUFACTURER_SPECIFIC
0x5A - COMMAND_CLASS_DEVICE_RESET_LOCALLY
0x87 - COMMAND_CLASS_INDICATOR
0x73 - COMMAND_CLASS_POWERLEVEL
0x9F - COMMAND_CLASS_SECURITY_2
0x6C - COMMAND_CLASS_SUPERVISION
0x7A - COMMAND_CLASS_FIRMWARE_UPDATE_MD
Command Class Information
GRNERIC DEVICE CLASS: 0x10 - SWITCH BINARY
SPECIFIC DEVICE CLASS: 0x00 – NOT_USED
100 feet
MEDICAL EQUIPMENT
CONTROLLING APPLIANCES
Over-temperature protection is protection against overheating of the protected equipment.
When the device's temperature is high, the LED will light up in red and cut down the power.
Please power off the device and use it after the temperature of the device drops.
Overloading
Warning
This parameter can access you to set a timer to make the switch turn off automatically after the switch turns on.
(LED flashes 3 times when the configuration parameter changed.)
--- Parameter =4, Size=4Value: 0– 65535(minutes);
Value=0(default) disable
Auto Turn-Off Timer
The numberentered as value corresponds to number of minutes. Operation: Set up on the hub.
LED Indicator
This parameter can access you to choose the LED indicator to be on when the plug(light) is on/off, or LED indicator remains
on/off all times. (LED flashes 3 times when the configuration parameter changed.)
Value=1 --- LED is On when switch (light) is Off.
--- Parameter =2, size =1byte, Default =0
Value=0 (default) LED is On when switch (light) is On.
Value=2 --- LED is always Off.
Value=3 --- LED is always On.
This parameter can access you to set a timer to make the switch turn on automatically after the switch turned on.
The numberentered as value corresponds to number of minutes.
(LED flashes 3 times when the configuration parameter changed.)
--- Parameter =6, Size=4Value: 0– 65535(minutes);
Value=0(default) disable turn on the outlet
Auto Turn-On Timer
Operation: Set up on the hub.
This parameter can access you to set a specific brightness for the light when you want to make it as a night light.
--- Parameter =7, Size=1, Default = 2
Value=1 --- 10% brightness
Value=2 --- 20% brightness
Value=10 --- 100% brightness
/
Night Light Set
(LED flashes 3 times when the configuration parameter changed.)
This parameter can access you to set the switch to be on/off after power failure.
Operation: quickly press 8 times to change this parameter.
Parameter=8Size=1Value=2(default)
Value=0 --- The switch is off regardless of the state prior to power failure.
Value=1 --- The switch is on regardless of the state prior to power failure.
Value=2(default) memory state before power failure
This switch will be return to state prior to the power failure after power is restored.
(LED flashes 3 times when the configuration parameter changed.)
This parameter can access you to set the time from maximum brightness to minimum brightness or minimum brightness to
maximum brightness (Only when turn ON / OFF the light )
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Value=0 --- instant on/off
Parameter=9Size=1, Default = 2
Value=1--- from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 --- from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
Value=10 --- from 0x63 to 0x00 or from 0x00 to 0x63 need 10s
/
This parameter can access you to set the time from maximum brightness to minimum brightness or minimum brightness to
maximum brightness.
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=10Size=1, Default = 4
Value=1 --- from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 --- from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
Value=10 --- from 0x63 to 0x00 or from 0x00 to 0x63 need 10s
/
(Only when hold it to change the brightness or control from HUB).
Operation: quickly press 5 times to change this parameter.
(LED flashes 3 times when the configuration parameter changed.)
Value=0 --- disable
Value=1
/
Value=99
---Parameter=11Size=1Default = 10
Value=1
/
Value=99
(LED flashes 3 times when the configuration parameter changed.)
---Parameter=12Size=1Default = 99
Value=0 --- disable
Operation: quickly press 10 times to change this parameter.
Multilevel minimum value can be set
Multilevel maximum value can be set
Restores state after power failure
Dimmer speed (ON/OFF Control)
Dimmer speed (Dimmer Control)
正面
背面
SIZE: 190 x 190 mm
材质:80G 书写纸
单色黑白印刷
拆法:风琴页 47 x 47 mm 成品
MP21ZD

Summary of content (1 pages)