Instructions / Assembly

NOTE:
NOTE:
The auto learning function will only
mandate within 60 seconds when turning the
fan’ s AC power ON.
1. Select desired frequency from the back of
transmitter.
2. Within 60 seconds of turning AC power on,
press and hold the " (Off)" button to enter the
learning function. Once the fan has detected the
remote controls's frequency, the down light of
your fan, if applicable, will blink, and the fan
blades will start to spin.
NOTE:
NOTE:
During self calibration test, the remote
will be non-function.
NOTE:
NOTE:
The learning frequency function and self
calibration test will continue to retain the last set
frequency and calibration set even when the AC
power is shut off. If the frequency is changed the
self calibration test will occur again.
1. Lock position: The DC motor has a built-in
safety against obstruction during operation. The
motor will get locked operation and disconnect
power after 30 seconds if interruption occurs.
Please remove obstacles before re-set.
2. Over 80W protection: When the receiver
detects motor power consumption which is
greater than 80W, the receiver’s power will stop
and operation will be immediately discontinued.
Turn the receiver power on after 5 seconds.