ULTRA BY INSTRUCTION MANUAL WARRANTY CERTIFICATE
Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws.
The Minka-Aire® warranty is for one (1) year from the date of purchase from an authorized Minka-Aire® dealer. This warranty is only valid to the original purchaser or user against all defects in material and workmanship (light bulbs excluded) for one (1) full year. Additionally, Minka-Aire® warrants the motor only for the lifetime of the Minka Aire ceiling fan (excluding wall controls and electrical components), to the original purchaser or user.
Warranty Service Information To obtain warranty service during the warranty period, the purchaser should return the fan with the sales receipt to the original place of purchase. The authorized Minka-Aire® dealer, at its sole discretion, will either repair or replace the fan after verifying the legitimacy of the warranty claim. Replacement is subject to availability of the same model. If the model is unavailable it will be replaced by one of equal value.
SAFETY RULES..................................................................................... 1 BLADE INSTALLATION........................................................................... 8 PACKAGE CONTENTS..................................................................... 2 ATTACHING THE SWITCH CUP.......................................................... 9 INSTALLING THE FAN..................................................................... 3 OPERATING THE REMOTE CONTROL/WALL CONTROL ......
1 SAFETY RULES 1. Before you begin installing the fan, shut power off at the circuit breaker of the fuse box. 2. Be cautious! Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams. 3. Make sure that all electrical connections comply with local codes, ordinances, or National Electrical Codes. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring. 4.
NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person (s) installing, caring for and operating the unit. NOTE: READ AND SAVE ALL INSTRUCTIONS! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR OTHER PERSONAL INJURY, MOUNT FAN ONLY TO A U.L.
2 PACKAGE CONTENTS 2 8 Unpack your fan and check the contents. You should have the following items: 1. Fan blades (5) 2. Hanger bracket 3. Canopy 4. Canopy cover 5. Coupling cover 6. Standard downrod ass'y 7. Minimum-length downrod (for close to the ceiling installation only) 8. Fan motor/housing ass'y 9. Blade holders (5) 10. Switch cup 11. Hand Held Transmitter+holder+2 mounting screws 12a. Wall transmitter Incl. 2 mounting screws and 3 wire nuts 12b. Wall plate w/2 mounting screws 13.
Tools Required: Phillips screw driver; slotted screw driver; step-ladder; wire cutters; electrical tape. MOUNTING OPTIONS INSTALLING THE FAN OUTLET BOX CROSS BRACE If there isn't an existing mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials.
4 HANGING THE FAN WARNING: All of the parts, hardware and components such as the hanger bracket and hanger ball have been provided for your safety and the proper installation of your new ceiling fan. The use of other parts, hardware or components not supplied by Minka Aire® with the fan will void the Minka Aire® Warranty. Step 4. Carefully feed fan wires up through the downrod. (Fig. 8) Thread the rod into the coupling, next line up holes and replace lock pin and hitch pin. Tighten set screws.
DOWNROD OUTLET BOX CROSS PIN DOWNROD SET SCREW SUPPLY WIRES SET SCREWS HITCH PIN LOCK PIN HANGER BALL COUPLING *OMIT COUPLING COVER WHEN USING THE MINIMUM-LENGTH DOWNROD CANOPY CANOPY COVER REGISTRATION SLOT SET SCREWS DOWNROD HANGER BRACKET Fig. 5 Fig. 6 Fig. 7 Fig. 10 Fig. 8 LOCK PIN Fig.
5 ELECTRICAL CONNECTIONS WARNING: To avoid possible electrical shock be sure electricity is turned off at the main fuse or breaker box before wiring. NOTE: The Aire Control® System is equipped with a learning frequency function which has 256 code combinations to prevent potential interference from other remote units. The frequency on your Receiver and Transmitter units have been preset at the factory. (Fig.
Step 3. Receiver to House Supply Wires Electrical Connections: Connect the WHITE wire (Neutral) from the outlet box to the WHITE wire marked "AC in N" from the receiver. Connect the BLACK wire (Hot) from the outlet box to the BLACK wire marked "AC in L" from the receiver. Secure all wire connections with the plastic wire nuts provided. (Fig. 13 & 14) RECEIVER HANGER BRACKET Step 4.
WHITE GREEN OR BARE COPPER (GROUND) WHITE ("AC IN N") AC SUPPLY BLACK BLUE (FOR LIGHT) BLACK (MOTOR) ORANGE (FOR UPPER LIGHT) BLACK BLACK BLUE BLACK WHITE ORANGE Fig. 13 GROUND Fig. 14 GREEN WHITE GROUND ORANGE BLUE BLACK WHITE ("TO MOTOR N") GROUND- (CONNECT TO (GREEN) GROUND WIRE ON HANGER BRACKE IF NO HOUSE GROUND WIRE EXISTS.
INSTALLING THE WALL TRANSMITTER (Wall Control Only) WARNING! HOOK UP "IN SERIES" ONLY. DO NOT CONNECT NEUTRAL SUPPLY WIRE OF ELECTRIC CIRCUIT TO THE TRANSMITTER WALL SWITCH, DAMAGE TO THE TRANSMITTER WALL SWITCH AND POSSIBLE FIRE COULD OCCUR. Step 1. Remove the existing wall plate and switch from the wall outlet box. Step 2. Make the electrical connections as shown in Fig.13.
7 FINISHING THE INSTALLATION Step 1. Remove 1 of the 2 screws from the bottom of the hanger bracket and loosen the other one half a turn from the screw head. Step 2. Slide the canopy up towards the hanger bracket and place the key hole on the canopy over the screw on the hanger bracket, turn canopy until it locks in place at the narrow section of the key holes. (Fig. 15) OUTLET BOX HANGER BRACKET HANGER BALL Step 3.
BLADE INSTALLATION THE FOLLOWING OPERATION MUST BE ACCOMPLISHED BEFORE INSTALLING THE LIGHT KIT. SCREWS Caution: Remove 5 rubber packing mounts and discard before installation. FIBER WASHERS Step 1. Attach the fan blade to the blade holder using the screws and fiber washers provided. Tighten screws securely. Repeat process for remaining blades.(Fig. 16) Step 2. Rotate the motor so that the screw holes in motor are aligned with the holes in blade holder and secure with proper screws.
9 ATTACHING THE SWITCH CUP Remove the screws from the switch cup plate. Slide switch cup up against plate and rotate it until the screw holes are aligned. Secure switch cup to plate using the screws removed earlier. (Fig. 18) NOTE: DO NOT PINCH WIRES BETWEEN THE SWITCH HOUSING AND THE SWITCH CUP PLATE. SWITCH CUP PLATE SWITCH CUP Fig.
OPERATING THE REMOTE CONTROL/WALL CONTROL Remote Control only: Install a A23 12 volt battery (included). To prevent damage to transmitter remove the battery if not used for long periods of time. instructions apply to ceiling fans that feature a DOWN D. OFF-ON Slide Button (Wall Control Fans Only) light ( button) only or ceiling fans that feature an UP This button turns the power Off and On to the Fan and A. Buttons: light ( button) and a DOWN light ( button) that are Light(s).
Speed settings for warm or cold weather depend on factors such as room size, ceiling height and number of fans. NOTE: To change the direction of the rotation of the blades the fan must be in operation mode. Warm Weather (forward) A DOWNWARD airflow creates a cooling effect as shown in Figure 19. This allows you to set your air conditioner on a warmer setting without affecting your comfort. Cool Weather (Reverse) An UPWARD airflow moves warmer air off the ceiling area as shown in Figure 20.
CARE OF YOUR FAN Here are some suggestions to help maintain your fan. 4. Use a lint free lightly damp cloth or duster to remove dust from the blades. 1. Because of the fan's natural movement some connections may become loose. Check the support connections, brackets and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from the ceiling). 5. There is no need to oil your fan. The motor has permanently lubricated bearings. 2.
12 TROUBLESHOOTING SYMPTOM Fan will not start SOLUTION Check to make sure the wall switch is turned on. Check circuit fuses or breakers. Caution! Make sure the power is turned off before performing the following steps. Remove canopy and check wire connections. If using a remote controlled fan; check to see that the dip switches from transmitter and receiver are set to the same frequency code. Check wall control transmitter connections (if applicable).
SYMPTOM Frequency Interference SOLUTION 1. Turn the power off to your ceiling fan. 2. Please use a small size tool to change the frequency settings on the control system. 3. Return power to the unit. Note: After the AC power is on, do not press any other button on the transmitter before pressing the "Stop" button, doing so will cause the procedure to fail. 4. Within 60 seconds of turning the Fan's AC power ON. Press the transmitter's "Stop" button and hold the "Stop¡" button for 10 seconds. 5.
13 SPECIFICATIONS These are typical readings. Your actual fan may vary. They do not include amps and wattage used by the light(s). Fan Size Speed 54" Low Medium High Volts 120 120 120 Amps Watts RPM CFM N.W. G.W. C.F. 0.31 0.47 0.64 2019 4147 6341 10.7 kgs 1.65' 12.2 33.7 76.4 65 124 201 11.
2019 4147 6341 12.2 33.7 76.