Installation Sheet

INSTALLATION INSTRUCTIONS
For Model #1008-PL
READ AND SAVE THESE INSTRUCTIONS
WARNING ! SHUT PO WER OFF AT FUSE OR CI R C U I T B R E AK E R .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
NOTE
Turn off the main power at the circuit breaker before installing
the fixture, in order to prevent possible shock.
GENERAL
All electrical connections must be in accordance with local
and national electrical code (N.E.C) standards. If you are
unfamiliar with proper electrical wiring connections obtain the
services of a qualified electrician.
Carefully unpack your new fixture and lay out all the parts in a
clear area. Take care not to lose any small parts necessary
for installation.
ASSEMBLY AND INSTALLATION
1. Turn off the power.
2. Remove the Wire Cover (10) by loosening the screw and
snapping the Wire Cover (10) with your finger.
3. Pull the supply wires and house ground wire out from the Outlet
Box (1)
4. Install the Canopy (2) to the Outlet Box (1) by using two
Mounting Screws (4) (Size: #8-32*0.5"L) (Note: The side of the
Canopy marked "GND" must face out.)
5. Position your fixture over the Outlet Box (1). Mark the location of
the two Slot Holes (8) located on the fixture body. Remove the
fixture body from the ceiling. Drill the two Holes (6) using the
appropriately sized drill bit. Insert the provided ceiling Anchors
(5) into the holes.
6. Make the wiring connections: Connect the house ground wire to
the fixture ground wire. Connect the white supply wire to the
white fixture wire; connect black supply wire to the black fixture
wire using wire connectors. Carefully tuck all wires back into the
Outlet Box (1).(See Fig.4)
7. Attach the Fixture Pan (13) to the Canopy (2) through the two
Downward Screws (3) and tight it with two Nuts (7)
8. Feed the two Anchor Screws (9) through the Slot Holes (8).
Tighten the Anchor Screws (9) into the ceiling Anchors (5) until
the fixture body is flush with the ceiling.
9. Follow the drawing #3 to install the wire cover. Snap the wire
cover with your hands, then secure to the Fixture Body with
Screw. (See Fig 3 )
10. Install the Tube (11). Please follow the wattage label located on
the fixture body. Do not exceed the recommend wattage. (NE
PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE)
(Simultaneously insert the pins into both ends of the fixture
and rotate the bulb until you hear and feel them lock into place)
11. Follow drawing #2 to install the Acrylic Lens (12). Hook the Clips
(14) of the lens to the curve edge of the Fixture Pan (13) (See
Fig.2)
12. The color correlated Temperature (CCT) for replacing the
recommended lamp is (4100K).
INSTALLATION IS NOW COMPLETED
The ballast in each of these models can be replaced by a
qualified electrician without cutting of wires and without
damage to the housing, trim, decorative elements or
carpentry to which the fixture is attached. See installation
steps for more detail.
Fig. 4
Use screw driver to loosen
the ballast screw and take it
out of fixture pan.
Insert the Ballast to the triangle
hole and then secure it by the
screw on the other end.
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
HOUSE
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
HOUSE
WIRES
Green
(Ground)

Summary of content (1 pages)