©2020 Minks Lighting Inc. Manual design and all elements of manual design are protected by United States Federal and/or State Law including Patents, Trademark, and/or Copyright Laws.
= The Minka-Aire® warranty is for one (1) year from the Life me > date of purchase from an authorized Minka-Aire® dealer. This warranty is only valid to the original purchaser or user against all defects in material and workmanship {light bulbs excluded) for one (1) full year. Additionally, Minka-Aire® warrants the motor only for the lifetime of the Minks Ire ceiling fan (excluding wall controls and electrical components), to the original purchaser or user.
CONTENTS SAFETY RULES PACKAGE CONTENTS INSTALLING THE FAN HANGING THE FAN .. ELECTRICAL CONNECTIONS FINISHING THE INSTALLATION BLADE INSTALLATION. INSTALLING THE LIGHT KIT PLATE INSTALLING THE 16W LED ASSEMBLE INSTALLING THE GLASS SHADE OPERATING YOUR FAN... CARE OF YOUR FAN TROUBLESHOOTING SPECIFICATIONS .. PN miniature, 1151 W.
SAFE TY RULES Before you begin installing the fan, shut power off at the circuit breaker of the fuse box. 2. Be cautious! Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams. 3. Make sure that all electrical connections comply with local codes, ordinances, or National Electrical Codes. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring. 4.
PACKAGE CONTENTS Unpack your fan and check the contents. You should have the following items: 1. Fan blades{5) 2. Hanger bracket 3. Canopy 4. Canopy cover 5. Coup ing cover 6. Standard down rod assembly{67 7. Fan motor/housing assembly 8. Light kit plate 9.16W LED assembly 10. Glass shade 11. Balancing kit Mounting hardware: Wire nuts(3! #8x3/4 Machine screws (2) #10x1.5Wood screws (2) 4mm Star washers (2) Metal washers (2) Lock washers (2) B.
INSTALLING THE FAN Tools Required: Phillips screw driver: slotted screw driver; step-ladder; wire cutters; electrical tape. MOUNTING OPTIONS If there isn't an existing mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the moving weight of the fan {at least 50 Ibsen.
HANGING THE FAN WARNING: All of the parts, hardware and components such as the hanger bracket and hanger ball have been provided for your safety and the proper installation of your new ceiling fan. The use of other parts, hardware or components not supplied by Minks Ai re®with the fan will void the Minks Aird® Warranty. REMEMBER to turn off the power. Follow the steps below to hang your fan properly: Step 1.
Step 5. Step 6. Slip coupling cover, canopy cover and canopy note down rod. (Fig 9) Carefully reinstall hanger ball onto rod being sure that cross pin is in the correct position, set screws are tighten and wires are not twisted. Now lift motor assembly into position and place hanger ball into hanger bracket. Rotate until the check groove has dropped into the registration slot and seats firmly. (Fig. 10) Rod should not rotate if this is done correctly.
ELECTRICAL CONNECTIONS REMEMBER to shut the power off at the circuit breaker or fuse box Follow the steps below to connect the fan to your house supply wires. Use the wire nuts supplied with your fan. Secure the wire nuts by wrapping the connection with electrical tape. Step 1. Connect the black {hot} wire from the ceiling to the black and the blue wires from the fan. Connect the white (Neutral} wire from the ceiling to the white wire from the fan. (Fig.11) Step 2.
FINISHING THE INSTALLATION Step 1. Tuck connections neatly into ceiling outlet box. Step 2. Remove one screw from the hanger bracket and loosen the other screw around 1/4. Step 3. Align the canopy up to ceiling and over the loose screw. Place the canopy into key hole and rotate canopy clockwise. (Figure 12) Step 4. Secure the canopy by use previous removed screw. Step 5. Place the canopy cover to the canopy and rotate canopy cover clockwise until it is locked into right position. (Figure 12) Fig.
INSTALLING THE LIGHT KIT PLATE CAUTION: To Reduce The Risk Of Electric Shock, Disconnect The Electrical Supply Circuit To The Fan Before Installing Light Kit. Step1. Remove 1of 3 screws from the mounting ring and loosen the other 2 screws. (Do not remove.} (Fig. 14) Step 2. While holding the light kit plate under your fan, firmly snap the wire connection plugs together. (Fig.14} Step. Place the key holes from the light kit plate over the 2 screws previously loosened from the mounting ring.
INSTALLING THE 16W LED ASSEMBLY CAUTION: To Reduce The Risk OF Electric Shock. Disconnect The Electrical Supply Circuit To The Fan Before Installing Light Kit. Step 1. Remove 1 of 3 screw from the pillar of light kit plate and loosen the other 2 screws. {Do not remove) (Fig.15) Step 2. While holding the 16W LED assembly under your fan, firmly snap the wire connection plugs together. (Fig.15) Step 3.
INSTALLING THE GLASS SHADE Attach the glass shade to the light kit plate by twisting tightly. {Fig.16) Attach the pull chain fob to the chain on the light kit assembly. (Fig.17} sla 4—— LIGHT KIT PLATE PULL CHAIN FOB — \_ Fla? 10
OPERATING YOUR FAN Restore power to ceiling fan and test for proper operation. Speed settings for warm or cool weather depend on factors such as the room size. Ceiling height. number of fans, etc. The Reverse switch is located on light kit assembly (Fig 18). Slide the switch to the Left for warm weather operation. Slide the switch to the Right for cool weather operation. NOTE: Wait for fan to stop before changing the setting of the slide switch.
CARE OF YOUR FAN Here are some suggestions to help maintain your fan. 1.Because of the fan's natural movement some connections may become loose. Check the support connections, brackets and blade attachment twice a year. Make sure they are secure {lt is not necessary to remove fan from the ceiling). 2 Clean your fan periodically to help maintain its new appearance over the years. Use only a soft brush or lint free cloth to avoid scratching the finish.
TROUBLESHOOTING SYMPTOM Fan will not start SOLUTION ® Check to make sure the wall switch is muted on. © Check circuit fuses or breakers. ® Caution! Make sure the power is turned off before performing the following steps. SYMPTOM Fan Sounds Noisy SOLUTION © Allow a 24 hour “break in" period. Most noises associated with a new fan will go away during this time. ® Make sure the screws that attach the fan blade holder to the motor hub is tight.
SPECIFICATIONS These are typical readings. Your actual fan may vary. They do not include amps and wattage used by the light (s). y P Fan Size Speed Volts Amps Watts RPM 120 024 kes kgs 2041 High 120 053 638 170 PERFORMANCE AND ENERGY INFORMATION Your Evy oy 2442 $11 2442 eis CI) | mee Iamb | en Sen do tun ams FAN SPEED AIRFLOW POWER USE AIRFLOW EFFICIENCY (CF* (watts) (CFMiweatt} Low 1946 13 149 High 4762 638 74 Ceiling fan allow Is measured In cubic feet per minute (CF. Power use Is measured In watts.