'.lifetime The: Minka-Aire® warranty is for one (1) year from the date of purchase from an authorized Minka-Aire® dealer. ’ This warranty is only valid to the original purchaser or user against all defects in material and workmanship {light bulbs sxcludedifor one {1] full year, Additionally, Minka-Aire® warrants the motor only for the lifetime of the Minks Ire ceiling faultfinding wall controls and electrical components] to the original purchaser or user.
Warranty Service Information To obtain warranty service during the warranty period, the purchaser should rectum the fan with the sales receipt t the original place of purchase. The authorized Minka-Aire® dealer, at its sole discretion, will either repair or replace the fan after verifying the legitimacy of the warranty claim. Replacement is subject to availability of the same model. ¥ the model is unavailable it will be replaced by one of equal value.
CONTENTS SAFETY RULES 1 INSTALLING THE LED & PACKAGE CONTENTS 2 INSTALLING THE LAMP SHADE 9 INSTALLING THE FAN 3 INSTALLING THE METAL SHADE e HANGING THE FAN .. 4 OPERATING THE REMOTE CONTROL/WALL CONTROL 1 ELECTRICAL CONNECTIONS 5 ENJOY YOUR SMART CEILING FAN 12 FINISHING THE INSTALLATION € CARE OF YOUR FAN.. 13 BLADE INSTALLATION .. 7 TROUBLESHOOTING “ SPECIFICATIONS .. 15 jn RQD TN ey @.
SAFETY RULES 1. Before you begin installing the fan, shut power off the circuit breaker of the fuse box, 2. Be cautious! Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams. 3. Make sure that all electrical connections comply with local codes, ordinance. or National Electrical Codes. EXPANSION 70, Hire 2 qualified electrician or consult a do-it-your self wiring handbook iF you are unfamiliar with installing electrical wiring. 4.
ATTENTION: The Energy Policy Act of 2005 requires this fan to be equipped with a 75 watt limiting devices, If laming exceeds Watts, the ceiling fan's light kit will shut off automatically. NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may scour. it must be understood that common sense. caution and care are factors which cannot be built into this product.
1. Fan blades{3} 2. Hanger bracket 3. Canopy 4. Canopy cover 5. Standard down rod disassembly) &. Coupling cover 7. Fan antler assembly 8. Flywheel 9. Z%VJV LED assembly & light plate 1. Fixing ring 11 PC Lens, 12, Metal shade 13, Transmitter + holder » mounting 14. screws + A23 12 volt battery Receiver (1) + wire mats (9} PACKAGE CONTENTS Unpack your fan and check the contents. You should have the following items: & Mounting hardware: Wire nuts{3) screws {2) #10x1.
Tools Required: Philips screw driver, slotted screw driver, step-ladder. wire cutters, electrical tape. MOUNTING OPTIONS ¥ there isn't an existing mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials.
HANGING THE FAN WARNING: All of the parts, hardware and components such as the hanger bracket and hanger ball have been provided for your safety and the proper installation of your new ceiling fan. The use of other parts hardware o components not supplied by Minks Withdraw the fan will void the Minks Warranted. REMEMBER to tum off the power. Follow the steps below to hang your fan properly: Step 1.
ELECTRICAL CONNECTIONS WARNING: To avoid possible electrical shack be sure electricity is muted off at the main fuse or breaker box before wiring. NOTE: The Ire Control® System for this DL mayor fans is equipped with a framing frequency function which has 32 code combinations to prevent potential interference from other remote units. The frequency on your Receiver and Transmitter units have been preset at the factory. {Fig.
Step 2. Gator te Receiver Electrical Connections: Connect the WHITE wire from the fan to the WHITE wire marked” Light R from the Repressive. Connect the BLUE wire from the fan to the BLUE wire marked "Light L from the Receiver. Connect the YELLOW wire from the fan bo the YELLOW wire marked” MOTOR 1" from the Receiver. Connect the RED wire from the fan to the RED wire marked” MOTOR 2° from the Receiver. Connect the GREY wire from the fan to the GREY wire marked’ MOTOR 3° from the Receiver. (Fig.13} Step 3.
FINISHING THE INSTALLATION Step 1. Tuck connections neatly into ceiling outlet box, Step 2. Remove one screw from the hanger bracket and loosen the other screw around 14", Step 3, Align the canopy up to ceiling and over the loose screw, Place the canopy into key hole and rotate canopy clockwise. (Fig. 14) Step 4.Secure the canopy by use previous removed screw. Step 5. Place the canopy cover to the canopy and rotate canopy cover clockwise until it is hocked Into right position. {Fig.
Step 1. Attach the fan blades to the fan motor assembly by using two blade straws {1/4" x 20mmi and metal nuts. Tighten screws and metal nuts security. 153 Step 2. Repeat the process for the other Step 3 Align holes in the Anywhere and the fan motor assembly and secure with the screw (174" x 20mm) . Ensure all the screws 174" 20mm} are tightened. (Fig.
INSTALLING THE LED Step 1. Remove 1 of 3 screws from the mounting ring and loosen the other 2 sowers, (Do not remove Step 2. Claps the key holes from the 26W LED assembly & light plate over the 2 screws previously loosened from the mounting ring, tum 25W LED assembly & light plate unit] it docks in place at the Gamow section of the key holes. Secure by tightening the 2 screws previously loosened and the one previously removed. {Fig. 17} Courting g Step 3. Firmly snap the wire connection plugs together.
INSTALLING THE LAMP SHADE Raise PC lens up against the light plate , secures it to fan by turning it clockwise unit] snug.
1f you want the fan to be non-light version, please kindly skip step of 'installing the lamp shade’ above and follow the procedure directly: Attach the metal shade to the light plate by twisting tightly. (Fig.20} Warning : Before you install the metal shade, please make sure the wire plugs between LED assembly and fan housing has been disconnected.
Your DC brush less mayor is equipped with a self B. &7 Reverse button; L learning frequency contra. This button is used to change the direction of Restore power to ceiling fan and test the the rotation of the blades; Forward for warm transmitter as below for proper operation: weather or reverse for coal weather. A1 2 3.
Note: The aunts leaning function will only mandate within 60 seconds when turning the f Fan's AC power ON. 1. Defect desired frequent from the back of transmitted. 2. Press the transmitter's "OF button, and hold the "Off button for over 10 seconds. Once the receiver has detected the frequency, the down light of your fan if applicable will blink twice. {There is no indication if your fan is not equipped with a light.
Speed settings for warm or cold weather depend on Factors such as room size, ceiling height and number of fans. MOTE: to change the direction of the rotation of the blades the far must be in operation mode. Warm Weather forward) A DOWNWARD airflow creates a cooling effect as shown in Figure 22. This allows you to set your air conditioner on a warmer setting without affecting your comfort.
ENJOY YOUR SMART CEILING FAN Note: Before moving on to leaning about your new smart ceiling fan, pleads be sure to test all your fans functionalities using your remote control fires. To enjoy all the potential of your new ceiling fan. You'll need to download the BOND HOME app. Available on the Google and Apple Play Store. Yot can use the QR code shown in (Fig. 24) to download the app. or you can download the app by visiting HTTP/ bondholder / app and follow the prompts.
Here are some suggestions to help maintain your fan, 1. Because of the fan’s natural movement some connections may become Cripes. Check the support connections, brackets and blade attachments twice 3 year. Make sure they are secure. (it is not necessary to remove Fan from the excelling. 2. Clean your fan periodically to help maintain its new appearance over the year, CAUTION: many common household cleaning products contain chemicals that could damage the finish of your fan. Use only a soft lint Free cloth.
TROUBLESHOOTING SYMPTOM SYMPTOM Far will not start Fan Sounds Noisy SOLUTION SOLUTION & Check to make sure the wall switch is muted on, s Allow a 24 hour " break in" priced. Most noises associated & Check circuit fuses or breakers. with a new fan will go away during this time. ® Caution] Make sure the power is turned off before performing the @ Make sure the screws that attach the fan blade holder to the following steps. motor hul is tight. # Remove canopy and check wire connections.
SYMPTOM Fan Wobble SOLUTION © NOTE: All blase sets are grouped by weight Because wood and plastic blades vary in density. the fen may wobble Evan though blades are matched, # Make sure outlet box is secured to building structure. if necessary use the wound resews provided to further secure outlet box to joist, @ Blake sure hanger bracket is secure to the outlet box. screws are tight.
SYMPTOM Frequent Interference SOLUTION 1T the power off to your ceiling fan. 2 Please use a small size too! to change the frequency settings on the control system. 3 Return power to the unit. Note: After the AC power is on, do not press any other button on the transmitter before pressing the "Stop” button, doing so will cause the procedure o fail 4 Within 60 seconds of muting the fan's AL power ON. Press the transmitter's "Stop” button and hold the "Stop” button for 10 seconds. 5.
SYMPTOM Does not connect to Wik home network SOLUTION If you are having trouble completing the Bond Home connection with your ceiling fan, adjustments to your router settings may be needed please go to the Help Center section in the app under the Settings for additional information and support WiFi resetting I you wish to clear the WiFi setting from the app For a specified fan.
SPECIFICATIONS These are typical readings. Your actual fan may vary. Fan Size Speed Volts Amps Watts RPM NW GW CF They do not include amps and wattage used by Low 120 009 512 50 the light {s}. Medium Low 120 .14 7.88 65 Medium 120 Q.22 1276 72 875 W 3387 Medium High 120 033 2014 90 ke ke High 120 046 2846 105 Extra High 120 060 3888 nz For any additional information about your e8" Minks Alar Ceiling fan, please write ta: Pt TI W.