Service Manual

SCANNER SECTION
2-7
II UNIT EXPLANATION
1.2.5 AE control
During AE scan, the CCD sensor provided on the ADB (A/D conversion board) reads the density level of
the original. The CPU on the SCB (System control board) process the data and, based on the results,
selects the γ correction curve that will best reproduce the original.
A. AE sampling range
(1) While in platen copying
Main scanning direction
Based on the original size recognized in the APS or out-of-original erasure mode, the range excepting
10mm in front and in rear.
Sub-scanning direction
The range of 30mm from the leading edge of the original. However, the range excepting L/100mm in
left and right when the length of the original is L mm.
[1] Original [3] AE sampling range
[2] Leading edge of original
10 mm
10 mm
30 mm
L mm
mm
L
100
mm
L
100
[1]
[2]
[3]