Instruction manual

CHAPTER 2 : OPERATION GUIDE
39
Preparing for
Measurement
Content displayed in list window
Instrument Instrument Name CS-2000 / CS-2000A / CS-200 / CS-100A / CS-1000
Variation
Standard Model (when the CS-2000 is connected)
Low Model (when the CS-2000A is connected)
XXXX-XXX (when the CS-200 is connected)
Model 1 / Model 2 (when the CS-1000 is connected)
Serial No. Serial No. of instrument
Firmware Version ROM version of instrument
Timestamp Day and time of measurement
Measurement Type Reflectance / Transmittance / Radiometric
Lens
Standard / Close up (when the CS-2000/2000A is connected)
Standard / Close up 1 (No. 107) / Close up 2 (No. 122) / User 1 / User 2
/ User 3 (when the CS-200 is connected)
Standard / Macro / Small measuring diameter /
Small measuring angle (when the CS-1000 is connected)
Measurement Angle 1° / 0.2° / 0.1° (only when the CS-2000/2000A or CS-200 is connected)
Measurement Speed
Normal / Fast / Multi / Manual (When the CS-2000 with ROM version
less than 1.10 is connected)
Normal / Fast / Multi (Normal) / Multi (Fast) / Manual (When the CS-
2000A is connected or when the CS-2000 with ROM version greater
than or equal to 1.10 is connected)
Auto / LTD. AUTO / S-Fast / Fast / Slow / S-Slow / Manual (when the
CS-200 is connected)
Fast / Slow (when the CS-100A is connected)
Auto (Normal) / Auto (Fast) / Manual (when the CS-1000 is connected)
Shown as “Manual xx.x(s)” when “Manual” is to be displayed. (Where
“xx.x” is the measurement speed in seconds at the time when the data
was measured.)
Measurement Mode
No-Sync / External / Internal (when the CS-2000/2000A is connected)
Internal / No-Sync (when the CS-200 is connected)
Internal / External/ No-Sync (when the CS-1000 is connected)
Shown as “Internal xxx.x(Hz)” when “Internal” is to be displayed.
(Where “xxx.x” is the synchronization frequency in hertz at the time
when the data was measured.) Note that the decimals are always dis-
played as “00” regardless of the actual synchronization frequency at the
time of measurement.
Calibration Channel
00 to 20 (when the CS-200 is connected)
00 to 10 (when the CS-2000/2000A is connected)
Calibration Mode
ND / Wavelength / Level / ND + Wavelength / Wavelength + Level / ND
+ Level / ND + Wavelength + Level (when the CS-2000/2000A is con-
nected)
Konica Minolta Standard / One-point calibration / User (when the CS-
200 is connected)
Konica Minolta Standard / User (when the CS-100A is connected)
Wavelength / ND / Level / Wavelength + ND / Wavelength + Level / ND
+ Level / Wavelength + ND + Level (when the CS-1000 is connected)
Observer 2 degree, 10 degree
Illuminant
A/B/C/D
50
/D
55
/D
65
/D
75
/D
95
/E/F
2
/F
6
/F
7
/F
8
/F
10
/F
11
/F
12
Integral Time Integral time
Meas.ID Measurement ID
ND [attachment]
None / ND1/10 / ND1/100 (only when the CS-2000/2000A is con-
nected)
ND [built-in] On / Off / Auto (Only when the CS-2000A is connected)
Warning
Over (brightness) / Over (chromaticity) / Over (brightness + chromatic-
ity) / Under (brightness) / Under (chromaticity) / Under (brightness +
chromaticity) / Insufficient exposure