Service manual
FrameMaker Ver5.5E(PC) CF3102/CF2002 DIS/REASSEMBLY, ADJUSTMENT
02.06.010
D-44
(2) Focus Positioning of the Scanner and 2nd/3rd Mirrors Carriage
This adjustment must be made in the following case:
• The Scanner Drive Cables have been rewound
.
(3) Scanner Position Adjustment
This adjustment must be made in the following case:
• The Scanner Drive Cables have been rewound.
• Focus Positioning of the Scanner and 2nd/3rd Mirrors Carriage must be completed.
1. Slide the 2nd/3rd Mirrors Carriage to the center
until it is pressed up against the cutouts in the
rails.
4025D122AA
2. Turn the cable length adjusting screw so that the
2nd/3rd Mirrors Carriage contacts the cutouts in
the rails.
4025D123AA
1. Slide the 2nd/3rd Mirrors Carriage to the position
shownontheleft.
4025D124AB
120 mm
2. SecuretheScannerinthepositionshownonthe
left using Scanner positioning Screws.
D-20
3. Make the FD-Mag. adjustment.
D-68
4025D125AB
30 mm