Service manual

FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T- 3 7
<Action>
C0010, C0012, C0014, C0016
C0011, C0013, C0015, C0017
Relevant Electrical Parts
IU Motor C (M17)
IU Motor M (M16)
IU Motor Y (M15)
IU Motor Bk (M18)
IO Board (PWB-IO)
DC Power Supply 1 (PU1)
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the connector of each
motor for proper connection
and correct as necessary.
——
2
Check the connector of each
motor for proper drive coupling
and correct as necessary.
——
3
Check the PU1 connector for
proper connection and correct
as necessary.
PU1 PJ7PU1-1 (DC24V) 28-G
4 M15 operation check T-3
PWB-IO PJ17IO-5A (LOCK)
PWB-IO PJ17IO-6A (REM)
16-A
5 M16 operation check T-3
PWB-IO PJ17IO-11A(LOCK)
PWB-IO PJ17IO-12A(REM)
17-B
6 M17 operation check T-3
PWB-IO PJ17IO-5B(LOCK)
PWB-IO PJ17IO-6B(REM)
16-C
7 M18 operation check T-3
PWB-IO PJ17IO-11B(LOCK)
PWB-IO PJ17IO-12B(REM)
18-C
8 Change PWB-IO. ——
9 Change PU1. ——
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1 M15 operation check T-3
PWB-IO PJ17IO-5A(LOCK)
PWB-IO PJ17IO-6A(REM)
16-A
2 M16 operation check T-3
PWB-IO PJ17IO-11A(LOCK)
PWB-IO PJ17IO-12A(REM)
17-B
3 M17 operation check T-3
PWB-IO PJ17IO-5B(LOCK)
PWB-IO PJ17IO-6B(REM)
16-C
4 M18 operation check T-3
PWB-IO PJ17IO-11B(LOCK)
PWB-IO PJ17IO-12B(REM)
18-C
5 Change PWB-IO. ——