Service manual

FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T- 3 8
(11) C0040: Suction Fan Motor’s failure to turn
(12) C0043: Cooling Fan Motor 1’s failure to turn
(13) C0044: Cooling Fan Motor 3’s failure to turn
(14) C0045: Cooling Fan Motor 4/5’s failure to turn
(15) C0046: Fusing Cooling Fan Motor’s failure to turn
(16) C004C: Ozone Ventilation Fan Motor’s failure to turn
(17) C004E: Power Supply Cooling Fan Motor’s failure to turn
(18) C004F: Cooling Fan Motor 2’s failure to turn
<Detection Timing>
Malfunction Code Description
C0040
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Suction Fan Motor is turning.
C0043
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Cooling Fan Motor 1 is turning.
C0044
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Cooling Fan Motor 3 is turning.
C0045
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Cooling Fan Motor 4/5 is turning.
C0046
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Fusing Cooling Fan Motor is turning.
C004C
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Ozone Ventilation Fan Motor is turn-
ing.
C004E
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Power Supply Cooling Fan Motor is
turning.
C004F
The Fan Lock signal remains HIGH for a predetermined continu-
ous period of time while the Cooling Fan Motor 2 is turning.