Service manual
FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T- 4 0
C0044
C0045
C0046
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the motor connector for
proper connection and correct
as necessary.
—— —
2
Check the fan for possible
overload and correct as neces-
sary.
—— —
3 M27 operation check T-3
PWB-IO PJ29IO-3(LOCK)
PWB-IO PJ29IO-1(REM)
35-B
4 Change PWB-IO. —— —
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the motor connector for
proper connection and correct
as necessary.
—— —
2
Check the fan for possible
overload and correct as neces-
sary.
—— —
3 M28, M29 operation check T-3
PJ25IO-4B(LOCK): M28
PJ25IO-2B(REM): M28
PJ25IO-9B(LOCK): M29
PJ25IO-7B(REM): M29
35-B: M28
35-C: M29
4 Change PWB-IO. —— —
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the motor connector for
proper connection and correct
as necessary.
—— —
2
Check the fan for possible
overload and correct as neces-
sary.
—— —
3 M24 operation check T-3
PU2 CN2PU2-9(LOCK)
PU2 CN2PU2-7(REM)
2-F
4 Change PU2. —— —