Service manual

FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T- 4 2
(19) C0060: Fusing Drive Motor’s failure to turn
(20) C0061: Fusing Drive Motor turning at abnormal timing
<Detection Timing>
<Action>
C0060
C0061
Malfunction Code Description
C0060
The Fusing Drive Motor Lock signal remains HIGH for a predeter-
mined continuous period of time while the Fusing Drive Motor is
turning.
C0061
The Fusing Drive Motor Lock signal remains LOW for a predeter-
mined continuous period of time while the Fusing Drive Motor
remains stationary.
Relevant Electrical Parts
Fusing Drive Motor (M14) IO Board (PWB-IO)
DC Power Supply 1 (PU1)
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the M14 connector for
proper connection and correct
as necessary.
——
2
Check the Fusing Unit drive for
possible overload and correct
as necessary.
——
3
Check the PU1 connector for
proper connection and correct
as necessary.
PU1 PJ6PU1-1(DC24V) 28-G
4 M14 operation check T-3
PWB-IO PJ5IO-7A(LOCK)
PWB-IO PJ5IO-10A(REM)
2-E
5 Change PWB-IO. ——
6 Change PU1. ——
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1 M14 operation check T-3
PWB-IO PJ5IO-7A(LOCK)
PWB-IO PJ5IO-10A(REM)
2-E
2 Change PWB-IO. ——