Service manual
FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T- 5 6
(51) C1200: Memory mounting failure
<Detection Timing>
<Action>
Malfunction Code Description
C1200
The WORK memory or Controller Board are not mounted on the
Image Control Board (PWB-F) when the printer controller
CN3102e is installed.
Relevant Electrical Parts
Image Control Board (PWB-F) Controller Board
WORK memory (DIMM Board)
Step Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Select “Tech. Rep. Mode”
→
“System Input” → “Peripheral
Setting” and check for correct
setting.
—— —
2
Check that WORK memory is
correctly mounted on the
Image Control Board (PWB-F).
—— —
3
Change WORK memory on
the Image Control Board
(PWB-F).
—— —
4
Change Controller Board on
the Image Control Board
(PWB-F).
—— —
5 Change PWB-F. —— —