Service manual

FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T- 7 1
4. IMAGE QUALITY PROBLEMS
4-1. Descriptions of the “State Confirm” Function of Tech. Rep.
Mode Concerning Image Quality Problems
As part of troubleshooting procedures, the numeric values set for State Confirmavail-
able from Tech.Rep.Modecanbeusedtoisolatethecauseoftheimageproblem.
(1) Table #
4025T568CA
Vb-C/-M/-Y/-Bk
Shows the developing bias value of each
color of toner when an image is produced.
Standard values: Around 400 V
Acorrectionismadetomaketheimage
lighter when the numeric value is greater.
Acorrectionismadetomaketheimage
darker when the numeric value is smaller.
<Relevant Components>
IU, High Voltage Unit (Developing Bias)
Vg-C/-M/-Y/-Bk
Shows the grid voltage value of each color
of toner when an image is produced.
Standard values: Around 550 V
Acorrectionismadetomaketheimage
lighter when the numeric value is greater.
Acorrectionismadetomaketheimage
darker when the numeric value is smaller.
<Relevant Components>
IU, High Voltage Unit (Developing Bias)
4025T569CA
4025T569CA