FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T- 7 6
(2) IR System: white lines in CD, white bands in CD, colored lines in CD, and col-
ored bands in CD
<Typical Faulty Images>
<Troubleshooting Procedure>
Section Step Check Item Result Action
Original 1 Original is damaged or dirty. YES Change original.
Original Cover 2 Original Pad is dirty. YES Clean.
Original Glass 3 Original Glass is dirty. YES Wipe the surface clean
with a soft cloth.
Machine Adjust
IR Area
Top Image
(Tech. Rep. Mode)
4 The adjustment value for Top
Image falls within the speci-
fied range.
Readjust.
5 The problem has been elimi-
nated through the checks of
stepsupto4.
NO Change Scanner Assy.
Change CCD Unit.