(19) Cleaning LPH Assy
NOTE
After the Imaging Unit has been removed from the main unit, be sure to place it in the
aluminum package or wrap it in a light shielding cloth, and store it in a dark place.
Do not leave the Imaging Unit exposed to light for a extended period of time, as it may
become damaged.
1. Open the Front Door.
2. Slide out the IU (C/M/Y/Bk).
E-22
3. Remove the LED Cleaning Jig and LED Cleaning
Jig Pad.
4025E014AA
4. Affix a LED Cleaning Jig Pad to the LED Clean-
ing Jig.
4025E015AA
5. Clean the LED of the LPH Assy by moving the
LED Cleaning Jig three reciprocating motions.
NOTE
Use only the specified jig (LED Cleaning Jig) for
cleaning.
4025E013AA