Service manual

RADF
1-P-5
3 DIS./ASSEMBLY1 DIS./ASSEMBLY
[2] Cleaning the Cleaning Pad
Caution
:
Make sure power cord of the main unit has
been unplugged from the wall outlet.
a. Procedure
(1) Open the Jam access cover.
(2) Remove one screw to detach the cleaning pad.
(3) Using a blower brush, clean the cleaning pad.
(4) Reinstall the above parts following the removal
steps in reverse.
[3] Replacing the Double Feed Preven-
tion Roller / Double Feed Prevention
Roller Rubber
Caution
:
Make sure power cord of the main unit has
been unplugged from the wall outlet.
a. Procedure
(1) Open the Jam access cover.
(2) Open the retaining clip and remove the double
feed prevention roller.
(3) Remove the double feed prevention roller rubber
from the double feed prevention roller.
(4) Reinstall the above parts following the removal
procedure in reverse.
Caution:
Make sure that the double feed pre-
vention roller is installed in the correct
direction.
2
1
3
4
1. Cleaning pad
2. Registration idler roller
3. Screw
4. Jam access cover
2
1
3
1. Jam access cover
2. Double feed prevention roller
3. Double feed prevention roller rubber