Service manual
LCT
1-Q-1
3 DIS./ASSEMBLY1 DIS./ASSEMBLY
PAPER FEED SECTION
[1] Cleaning the Paper Dust Removing
Brush
Caution:If LT is connected to the main
body, make sure that main body
power plug is disconnected
from the power outlet.
a. Procedure
(1) Open the top cover.
(2) Remove six screws to detach the paper feed
cover B.
(3) Insert a flat bladed screwdriver in the cavities (in
two locations) for paper dust removing brush to
release the locking lugs, then remove the paper
dust removing brush.
(4) Clean the paper dust removing brush using a
blower brush.
(5) Reinstall the above parts following the removal
steps in reverse.
[2] Cleaning the LT feed PS (PS106)/LT
first paper feed PS (PS107)
Caution:If LT is connected to the main
body, make sure that main body
power plug is disconnected
from the power outlet.
a. Procedure
(1) Looking into the paper exit side of the LCT from
below, and clean sensors through the cavity for
LT feed PS (PS106) and the cavity for LT first
paper feed (PS107) using a blower brush.
Top cover
Screws
Paper feed cover B
Paper dust removing brush
Locking ligs
Cavity
Cavity for PS107
Cavity for PS106
Paper exit side