Service manual

LCT
1-Q-7
3 DIS./ASSEMBLY1 DIS./ASSEMBLY
(10) Remove three screws to detach the up/down
motor assembly.
(11) Replace the up/down wire following the instruc-
tions in “Removing Up/Down Wires’’ and “Install-
ing Up/Down Wires.’’
Caution:
Two sets of four up/down wires with
different length, one set at the front
and the other at the back, are used.
Wires with the same length can be
used either at the front or back if they
are used in the same location.
2
1
12
6
7
5
3
3
8
3
9
9
10
11
4
1. Up/down motor mounting assembly
2. Relay connector (CN749)
3. Screw
4. Relay connector (CN780)
5. Relay connector (CN781)
6. Relay connector (CN782)
7. Relay connector (CN783)
8. Up/down gear
9. E-ring
10. Pin
11. Bearing
12. Shaft
Wire A
Wire B
Wire C
Wire D
1323.6 mm
1250.3 mm
769.3 mm
661 mm