Service manual

FN
1-R-4
3 DIS./ASSEMBLY1 DIS./ASSEMBLY
[7] Removing and Reinstalling the Main
Tray
Caution
:
After you have lowered the main tray, be
sure to unplug the power cord of the main
body from the power outlet.
a. Procedure
(1) Push up the actuator of the main tray exit with
your finger to lower the main tray.
(2) Turn the main body's main power switch (SW1)
OFF, and unplug the power cord from the power
outlet.
(3) Remove the two mounting screws.
(4) Lift the main tray and detach it from the hooks of
the up/down stay.
(5) Reinstall the above parts following the removal
steps in reverse.
Actuator
Paper exit roller
Main tray
Paper exit roller
Screws
Up/down stay
Main tray