Service manual

ADJUSTMENT
2-24
2 ADJUSTMENT
3. Viewing Collecting Data No.7 to No.12
Note:
On the Individual Data View screen show-
ing the JAM count of each section (col-
lected data ) or SC count of each
section (collected data ), the
key appears.
Pressing the key resets
the selected data count.
Step Operation
1 Enter the 25 mode.
2
[Memory setting mode menu Screen]
Select " Software DIP SW setting".
3
[Software DIP SW Setting Screen]
Set bit 1 of DIP switch 30-1 to 1.
4
Press the key to return to the
Memory setting mode menu Screen.
5
[Memory setting mode menu Screen]
Select " Data Collection".
6
[Collecting data menu Screen]
Select the collected data you want to
view by pressing one of numeric keys
to .
To select the key or later press the
key.
If the key is pressed with key
displayed, the Collected Data Selection
screen containing keys to
appears again.
7
[Individual data view Screen]
View the selected data by scrolling the
screen using the and keys.
(Note)
8
Press the key to return to the
Memory setting mode menu Screen.
1
RETURN
4
7 12
11
11
1 12
RETURN
11
12
COUNT RESET
COUNT RESET