Service manual

ADJUSTMENT
2-35
2 ADJUSTMENT
42 32 4
Paper exit fan/F lock
9999
All counters are 4-
digit counters.
43 33 1
Second paper feed MT EM
44 34 1
Fixing upper roller high temperature error
detection
45 34 2
Fixing upper roller high temperature error
detection
46 35 1
Fixing upper roller low temperature error
detection 1
47 35 2
Fixing upper roller low temperature error
detection 2
48 35 3
Fixing upper roller low temperature error
detection 3
49 36 1
Fixing upper roller sensor error detection
50 36 2
Fixing lower roller sensor error detection
51 41 1
Scanner HP return error
52 41 2
Polygon MT error
53 42 1
Scanner cooling fan lock
54 42 2
Write section cooling fan lock
55 46 1
APC error
56 46 2
Scanner FIFO error
57 46 3
Printer FIFO error
58 46 5
Compressed input/output FIFO error
59 46 6
Expansion error
60 46 8
Index sensor error
61 46 10
No margin of scanner control
62 46 11
No margin of printer control
63 46 12
SVV length error
64 46 13
Scanner time-out
65 46 14
Printer time-out
66 46 15
Expansion device access error
67 46 16
Compression device access error
68 46 17
Filter factory error
69 46 19
Memory device access error on data flow
70 46 21
Data flow memory mode time-out
71 46 23
SVV off error
72 46 24
Black/white collection error
73 46 25
AOC/AOG Level adjustment error
74 46 26
Invalid correction data by resolution
75 46 27
Density conversion (
γ
curve generation
error)
76 46 30
Calibration abend
77 46 31
APC initial sampling error
78 46 32
MPC error
79 46 33
Sub-scan beam correction error
80 46 34
Unfinished Calibration
81 46 35
Continuous copy page area error
NO
Trouble
code
Description
Maximum
count
Remarks