Service manual
ADJUSTMENT
2-43
2 ADJUSTMENT
[9] Copy Count by Parts to be Replaced
(Optional Parts)
This function allows you to make the following settings
for an optional part or data:
1. Copy count resetting
2. Limit value setting
3. Part number setting
4. Part name setting
The above settings can be made for 30 data numbers,
No.1 to No.30.
The copy count is incremented by 1 for each side irre-
spective of the paper size.
1. Resetting the Copy Count by Parts to be
Replaced (Optional Parts)
This function allows you to reset the copy count
by parts to be replaced (optional parts).
Reference:
If the copy count exceeds the limit,
the * mark appears to the left of the
limit value.
2. Changing the data on the Copy Count by Parts
to be Replaced (Optional Parts)
This function allows you to change the limit value, part
number, or part name for the desired optional copy
count by parts to be replaced (optional parts).
Step Operation
1 Enter the 25 mode.
2
[Memory setting mode menu Screen]
Select the " Parts counter".
3
[Copy count of part menu Screen]
Select the " Count of each parts".
4
[Copy count of each part Screen]
Data numbers (No.), part names
(Name), part numbers (P/N), and count/
limit values are displayed in a list format.
Using and keys, select a part
name.
To scroll the screen, use and
keys.
5
Press the key to reset
the count value of the part highlighted.
6
Press the key to return to the
Memory setting mode menu Screen.
5
2
COUNT RESET
RETURN
Step Operation
1
Enter the 25 mode.
2
[Memory setting mode menu Screen]
Select the " Parts counter".
3
[Copy count of part menu Screen]
Select the " Count of each parts".
4
[Copy count of each part Screen]
Data numbers (No.), part names
(Name), part numbers (P/N), and count/
limit values are displayed in a list format.
Using and keys, select a data
number.
To scroll the screen, use and
keys.
5
Press the Part Name Set, P/N Set, or
Limit Set key.
6
[Data change screen by parts to be
replaced]
Press the , or
key corresponding to the
data you want to change.
7
Enter new data using alphabetic and
numeric keys.
8
Perform steps 6 and 7 repeatedly to
change other data.
9
Press the key to allow the new
data to take effect.
To cancel the new data, press the
key.
Pressing either key will display the Copy
count by parts to be replaced (optional
parts) screen again.
10
[Data change screen by parts to be
replaced]
Press the key to return to
the Memory setting mode menu Screen.
5
2
Parts name P/N set
Limit set
OK
CANCEL
RETURN