3 DIS./ASSEMBLY1 DIS./ASSEMBLY
(4) When changing the operation panel attachment
angle, align the operation panel stopper with the
stopper hole at the front side on the bottom of the
operation panel and fasten using two screws in
the operation cover attachment holes.
Caution1:
To remove the operation panel, skip
this step and proceed to step (5).
Caution2:
When the attachment angle of the
operation panel is changed, the
operation panel cover and two
screws will become unnecessary.
(5) Remove the relay connectors (CN163, 164).
Caution:
Each relay connector consist of two
male sides and one female side. Be
sure to remove only the male side
(shown below).
(6) Remove screws to remove the Ground terminal.
(7) Remove the operation panel.
(8) Reinstall the above parts following the removal
steps in reverse.
2
1
3
4
1
1
2
1. Stopper hole
2. Operation panel stopper
3. Operation panel
4. Screws
2
1
5
3
4
1
5
1. Ground terminal
2. Relay connectors (CN163)
3. Relay connectors (CN164)
4. Operation panel
5. Screws