Service manual

ELECTRIC PARTS LIST
4-47
3 DIS./ASSEMBLY
4 ELECTRIC PARTS LIST
For the following abnormalities, the user can disconnect the faulty unit temporarily to continue using the
machine.
When an abnormality occurs, press the reset button following the LCD message, and turn the SW2 (sub
power) OFF/ON. This allows temporary use of machine until the SW2 (sub power) is turned OFF/ON next
time.
Warning code Cause Unit to be disconnected
F18-10 Tray 1 up drive motor abnormality
Tr ay 1
F18-11 Tray 1 up abnormality
F18-20 Tray 2 up drive motor abnormality
Tr ay 2
F18-21 Tray 2 up abnormality
F18-30 Tray 3 up drive motor abnormality
Tr ay 3
F18-31 Tray 3 up abnormality
F13-02 LCT paper feed motor abnormality
LCT
F18-50 LCT UP/DOWN motor abnormality
F46-40 to 43 HDD abnormality HDD
F62-01 DF motor cooling fan abnormality RADF
F77-22,25,26 Fold, stitch and fold, three-fold abnormality Fold,
stitch and fold, three-fold
F71-41 to 43 PI abnormality PI