Service manual

SCANNER SECTION
1-C-6
3 DIS./ASSEMBLY1 DIS./ASSEMBLY
[6] Cleaning the Slit Glass and Platen
Glass
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
(1) Remove the original stopper plates (left and
rear), platen glass, and top cover (right, left, front
center, and rear center). (See "EXTERNAL SEC-
TION.")
(2) Remove two screws to detach the slit glass.
(3) Place the removed slit glass and platen glass on
a rag and clean with drum cleaner and cleaning
pad.
(4) Reinstall the above parts following the removal
steps in reverse.
Screws
Screws
Slit glass
Slit glass