Service manual

DRUM UNIT
1-E-1
3 DIS./ASSEMBLY1 DIS./ASSEMBLY
DRUM UNIT
[1] Removing and Reinstalling the Drum
Unit
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
Caution1:
Be sure to put a drum cover over the
removed drum unit and store the
drum unit in a dark place.
Caution2:
When installing or removing the
drum unit, do not rotate it in the direc-
tion opposite to the specified one.
Rotating the drum unit in the oppo-
site direction during copy operation
could damage the cleaning blade.
Caution3:
When installing or removing the
drum unit, take care not to touch the
separation claw.
a. Procedure
(1) Open the left and right front doors.
(2) While pressing the solenoid release lever on top
of the ADU rack to the left, flip the ADU rack pull-
out lever to the left.
(3) Loosen three screws to remove the drum cover.
(4) Remove the two screws securing the drum unit.
(5) Release the toner supply pipe in the direction of
the arrow.
(6) Remove the screw securing the coupling to
detach the drum shaft coupling and drum cou-
pling.
(7) Hold the two sections shown in the figure and pull
out the drum unit.
(8) Reinstall the above parts following the removal
steps in reverse.
Caution:
To install the coupling, see "[2] Install-
ing the Coupling."
2
1
3
4
1. Drum cover
2. Screws
3. ADU rack pullout lever
4. Solenoid release lever
2
1
6
5
3
4
6
1. Drum unit
2. Toner supply pipe
3. Hold here
4. Drum shaft coupling
5. Drum coupling
6. Screws