(3) Removal of the Scanner Drive Cable
D Remove the Original Cover, Original Scales, and Original Glass.
D Remove the Middle Right, Upper Right, Right, Upper Left, and Upper Rear Covers.
D Remove the Left and Right Hinge Covers, Rear Upper Cover (Small), and Rear Upper Cover.
6. Temporarily secure the longer length of the Cable to the
Cable Fixing Bracket, ensuring a distance of 5 ± 2 mm for
the dimension shown on the left.
7. Wind the shorter length of the Cable around the Pulley
which is nearer to the Cable Drive Gear.
8. Hook the spring onto the shorter length of the Cable and
pull it to hook onto the longer length of the Cable.
9. Check that the dimension noted in step 6 above measures
5 ± 2 mm. Then, secure the Cable Fixing Bracket.
10. Remove the wrench and peel off the two pieces of tape.
1. Align the Scanner with the rectangular hole in the upper
copier frame and remove the screw from the Scanner Fix-
ing Bracket.
2. Remove the Fixing Bracket.
3. Unhook the spring to remove the shorter length of the