Specifications
Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-26
2-6. Imaging Unit
(1) Disassembly, Cleaning, Replacement and Starter Changing of the Imag-
ing Unit
1151D044AA
Replacement of the PC Drum
Replacement of the Toner Scattering Prevention Plate
1. Remove the Imaging Unit from the copier.
2. Remove two screws and the Imaging Unit Cover.
3. Remove one screw and the PC Drum Charge Corona Unit.
4. Remove two screws and one Drum Pin to remove the PC
Drum.
NOTE
Whenever the PC Drum has been replaced, be sure to
make the “Adjustments of the Optimum Exposure Setting
in the Manual and Auto Mode.” See pp. D-47 to D-48.
5. Remove one screw, one shoulder screw and the Toner
Scattering Prevention Plate.
6. Tilt the Developing Unit to remove the developer.