Specifications

Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-29
Cleaning of the Upper Pre-Image Transfer Guide Plate
Cleaning of the Magnet Roller Lower Filter
NOTE
At reinstallation, press the Toner Antispill Mylar up against
the Imaging Unit Housing and the rear side of the copier
(in the directions of the arrows) and press the Bias Seal up
against the Imaging Unit Housing and the front side of the
copier (in the directions of the arrows).
17. Remove two screws and the Upper Pre-Image Transfer
Guide Plate.
18. Using a brush, whisk toner and dust off the surface of the
Upper Pre-Image Transfer Guide Plate.
19. Using a brush, whisk toner and dust off the Magnet Roller
Lower Filter.
(No Magnet Roller Lower Filters are mounted in the copi-
ers for the U.S.A., Canada, and Europe.)
20. Refit the parts to the Imaging Unit and reinstall the Imaging
Unit in the copier.
21. Charge fresh starter and make the ATDC adjustment. See
p. D-49.