Specifications
Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-32
2-7. PC DRUM CHARGE CORONA/IMAGE TRANSFER CORONA UNIT
(1) Cleaning of the PC Drum Charge Corona Housing
1151D037AA
(2) Cleaning of the PC Drum Charge Corona Grid Mesh
1. Remove the Imaging Unit.
2. Remove one screw and PC Drum charge Corona Unit.
3. Press the Mesh Holder on the front of the Corona Unit in
the direction of arrow A to remove the Grid Mesh.
4. Remove the Cleaning Pad Cover.
5. Remove the End Caps from the front and rear ends of the
Unit.
6. Remove the Comb Electrode.
NOTE
Use care not to deform the Electrode. When removing it,
first snap off its spring end.
7. Using a soft cloth dampened with alcohol, wipe the Hous-
ing clean of dirt.
1. Blow all foreign matter off the Grid with a blower brush.
NOTE
If the blower brush is not effective in cleaning the Grid, use
a soft cloth dampened with alcohol to clean serious con-
tamination.