Specifications

Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-33
(3) Cleaning of the Comb Electrode
(4) Cleaning of the Image Transfer/Paper Separator Coronas Wires
(5) Cleaning of the Image Transfer/Paper Separator Coronas Housing
1. Clean the Comb Electrode using the Corona Unit Cleaning
Lever.
1. Clean the Image Transfer Corona Wire using the Corona
Wire Cleaning Lever.
2. Remove the four Paper Guides.
3. Dampen a soft cloth with alcohol, hold it with a pair of twee-
zers, and wipe the Paper Separator Corona Wire gently in
one direction.
(Go from the hook to spring end.)
1. Remove the four Paper Guides.
2. Remove the two End Caps.
3. Remove the Image Transfer and Paper Separator Corona
Wires.
NOTE
When removing the Wire, unhook the spring end first
and use care to prevent break and deformation. (Use a
pair of tweezers)
Keep the Corona Wire Cleaning Lever (for the Image
Transfer Corona) pressed all the way back in. Do not
attempt to remove the Lower Pre-Image Transfer Guide
Plate as it has been adjusted for correct height.
4. Using a soft cloth dampened with alcohol, wipe the Hous-
ing clean of dirt.