Specifications
Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-52
(7) Adjustment of the 1st Drawer Reference Position
z Requirement
z Important
D If the Paper Tray of the Drawer needs to be moved for adjustment, make sure that it is moved straight,
not slantwise (as skewed feeding of paper could result).
D Ready a test chart (A3 or 11” 17”) as shown on the left.
Draw a line on the chart at a point 20 mm from the right
edge as shown.
D Dimension A on the copy should measure 20 ± 2.0 mm.
1. Place the test chart face down on the Original Glass and
align its rear left corner with the marker on the Original
Width Scale on the left side of the platen.
Then, lower the Original Cover.
2. Using the 1st Drawer, make two full size copies.
(Use A3 or 11” 17” paper.)
3. Using the second copy, compare the position of the refer-
ence line on the copy with that on the test chart.
4. If the line does not meet the requirement, slide out the 1st
Drawer, loosen the four screws shown on the left, and
move the Paper Tray as necessary to the front or rear.
NOTE
If dimension A on the copy is smaller than 18 mm, move
the Paper Tray to the rear. If it is more than 22 mm, move
the Paper Tray to the front.