(8) Adjustment of the Leading Edge Registration
Full Size
z Requirement
D Setting value range: 30 to 70
D Movement equivalent to 1 step of setting value: 0.28 mm
z Important
D After having set the copier into the Adjust Mode, make two single copies and use the second copy for
the check. (The first copy represents the data before adjustment.)
D When full size leading edge registration has been adjusted, it affects leading edge registration in the
enlargement and reduction mode. Be sure, therefore, to check for registration in these modes, too.
D Ready a test chart (A3 or 11” 17”) as shown on the left.
Draw a line across the test chart at a point 20 mm from
the leading edge and use it as the reference line.
Dimension A at the center on the copy should meet the
following requirements.
Mag. Ratio Dimension A (mm)
Full Size (100 %)
Enlargement (200 %)
Reduction (50 %)
20.0 ± 1.5
40.0 ± 3
10.0 ± 1.5
1. Place the test chart face down on the Original Glass and
align its rear left corner with the marker on the Original
Width Scale on the left side of the platen. Then, lower the
Original Cover.
2. Make two single copies in full size mode (100 %) and
check for leading edge registration on the second copy.
(If it meets the requirement, go to “Adjustment of Enlarge-
ment Leading Edge Registration.”)