Specifications
Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-60
3-5. OTHER ADJUSTMENTS
(1) Adjustment of the Scanner/Mirrors Carriage Position
z Requirement
D With the Scanner positioned correctly with reference to the upper copier frame, there should be no gap
between the Scanner/Mirrors Carriage and the Scanner/Mirrors Carriage Positioning Jig.
1151D055AA
1. Remove the Original Cover, Original Scales, and Original
Glass.
2. Temporarily tighten the screw on the Scanner Drive Cable
Holding Bracket.
3. Align the rectangular hole in the upper copier frame with
the U-groove in the Scanner, then insert the Scanner Posi-
tioning Jig into the hole.
4. Install the Scanner/Mirrors Carriage Positioning Jig be-
tween the Scanner and Mirrors Carriage.
5. Loosen the screw that has been temporarily tightened in
step 2. Turn the helical gear of the Scan Pulley to press the
Mirrors Carriage up against the Scanner/Mirrors Carriage
Positioning Jig and the Scanner.
6. Tighten the screw on the Scanner Drive Cable Holding
Bracket.