Specifications
Interleaf EP1052 DIS/REASSEMBLY, ADJUSTMENT
96.11.01
D-61
(2) Adjustment of the Gap Between the Doctor Blade and Sleeve Roller
z Requirement
D The gap between the Doctor Blade and the Sleeve Roller should be 0.35 mm ± 0.05 mm.
z Important
D Cover the PC Drum with the Drum Cloth to prevent it from being scratched.
1. Remove the Developer Scattering Prevention Plate.
2. Wipe the developer off the surface of the Sleeve Roller.
3. Install the Sleeve/Magnet Roller Positioning Jig onto the
Imaging Unit.
4. Loosen the three screws securing the Doctor Blade in
position. Insert the D.B. Adjusting Jigs into the space be-
tween the Doctor Blade and Sleeve Roller.
5. Press down the Doctor Blade until it positively contacts the
D.B. Adjusting Jigs, then tighten the three screws to se-
cure it in position.