Specifications
Interleaf EP1052 TROUBLESHOOTING
96.11.01
T-15
z Bypass Port Misfeed Clearing Procedure
Symptom
Step Check Item Result Action
1
Does the misfeed occur
when the Manual Bypass
Table is used?
YES
Perform the troubleshooting
procedure for
”Transport/Separator
Misfeed.”
2
Is paper taken up and fed in
properly from the Drawer?
NO
Perform the troubleshooting
procedure for ”Copier
Take-Up and
Transport/Separator
Misfeed.”
D Paper is not taken
up at all.
3
Is the paper being used up
to product specifications?
NO
Instruct the user to use the
paper that is up to product
specifications.
4
Is the paper curled, waved,
or damp?
YES
Change the paper.
Instruct the user in how to
store the paper.
5
Are the Paper Take-Up
Rolls pressed against the
paper stack when the Start
Key is pressed?
* Does the voltage across
YES
Adjust the stroke of the
Solenoid.
Check the Solenoid.
PJ11A-2 on PWB-A and
GND change from DC24V
to DC0V when the Start
Key is pressed?
NO
Replace PWB-A.
Does the voltage across
PJ7A-5 on PWB-A and
YES
Check the Clutch.
6
GND change from DC24V
to DC0V when the Start
Key is pressed?
NO
Replace PWB-A.
7
Is the Pressure Pad or
Guide Plate deformed or
dirty?
YES
Clean or replace the
Pressure Pad or Guide
Plate.
8
Are the Paper Take-Up
Rolls deformed, worn, or
dirty with paper dust?
YES
Clean or replace the Paper
Take-Up Rolls.
D Paper is
stationary near
the Transport
9
Check Transport Roller
Sensor PC51 Seep. T-3
(PWB-A (IC4A) APC7).
NO
Check the Actuator for
operation.
Check PC51.
Roller.
Does the voltage across
PJ6A-6 on PWB-A and
YES
Check the Clutch.
10
GND change from DC24V
to DC0V when the Start
Key is pressed?
NO
Replace PWB-A.
11
Is the Transport Roller or
Guide Plate of the copier
deformed, worn, or dirty
with paper dust?
YES
Clean or replace the
Vertical Transport Roller or
Guide Plate.